Background:
The aim of this study is to retrospectively evaluate the safety and effectiveness of forceps-assisted removal of difficult-to-retrieve filters.
Methods:
Patients who underwent forceps-assisted removal of difficult-to-retrieve filters (filters that could not be successfully removed with the standard loop-snare technique) between February 2008 and February 2019 were included in this study. Patients underwent forceps-assisted filter removal either immediately after failed loop-snare removal (same procedure) or at a later time (separate procedure). Data regarding success rate, X-ray exposure time, and complications were recorded.
Results:
A total of 27 patients (14 men, 13 women; mean age 57.9 ± 12.6 years) were included in this study. The mean indwelling time of the filters was 10.9 ± 10.7 months. All filters were successfully removed. The mean X-ray exposure time was 25.9 ± 12.7 min (range 8-55) for all patients; the mean X-ray exposure times were 10.2 ± 2.3 min (range 8-14) for the 5 patients who underwent forceps-assisted filter removal in a separate procedure and 29.5 ± 11.2 min (range 15-55) for the 22 patients who underwent forceps-assisted filter removal immediately after failure of the loop-snare technique (P < 0.001). Two patients (8.3%) experienced extravasation of contrast material and needed no additional treatment. No major complications occurred.
Conclusions:
Forceps-assisted filter retrieval can be used to safely and effectively remove difficult-to-retrieve filters.
Related Concept Videos
Retrieval
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
ER Retrieval Pathway
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
Active Filters
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis