Simultaneous determination of alflutinib and its active metabolite in human plasma using liquid chromatography-tandem

Xiaoyun Liu1, Wei Li2, Yifan Zhang2

  • 1Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201210, China; University of Chinese Academy of Science, Beijing 100049, China.

Alflutinib, or known as AST2818, is an irreversible tyrosine kinase inhibitor that selectively inhibits EGFR mutations, especially T790M. At present, alflutinib has undergone phase II/III clinical trials for non-small cell lung cancer (NSCLC) treatment in China. The present study aimed to analye the pharmacokinetics of alflutinib and its active metabolite AST5902 in a plasma sample of NSCLC patient. A sensitive and highly selective method was optimized and validated for the detection of alflutinib and AST5902 using a liquid chromatography-tandem mass spectrometry. After precipitating proteins with acetonitrile, alflutinib, AST5902 and AST2818-d3 (internal standard) were analyzed with a Waters BEH C18 column. The mobile phase was optimized with acetonitrile: ammonium acetate (2 mmol/L) containing 0.2% formic acid using gradient elution. Separation was achieved within a total chromatographic running time of 2.1 min. Quantification was carried out using positive ion multiple reaction monitoring mode at ion transitions m/z 569.3→441.2, 555.1→498.2 and 572.3→441.2 for alflutinib, AST5902 and AST2818-d3, respectively. An excellent linearity was observed for alflutinib and AST5902 within concentration ranges of 0.20-100 and 0.050-25.0 ng·mL-1, respectively. Notably, the lower limit of quantification for alflutinib and AST5902 were 0.20 and 0.050 ng/mL, respectively. The intra- and inter-day accuracy of alflutinib were 0.7-2.9%, while its intra- and inter-assay precision were ≤9.1% and ≤10.5%, respectively. The accuracy of AST5902 was within -0.2-3.9%, while the intra- and inter-assay precision were ≤8.0% and ≤8.6%, respectively. The recoveries of the analysts remained constant and could be reproduced at different concentrations. Furthermore, this analytical method could be applied to determine the pharmacokinetic analysis of alflutinib and AST5902 in human plasma.

Related Concept Videos

Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.4K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.1K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.6K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.3K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
1.9K
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
3.4K