Polysomnographic Endotyping to Select Patients with Obstructive Sleep Apnea for Oral Appliances
Ahmad A Bamagoos1,2,3,4, Peter A Cistulli1,2, Kate Sutherland1,2
1Sleep Research Group, Charles Perkins Centre, University of Sydney, Sydney, New South Wales, Australia.
Abstract:
Rationale: Oral appliance therapy is efficacious in many patients with obstructive sleep apnea (OSA), but prediction of treatment outcome is challenging. Small, detailed physiological studies have identified key OSA endotypic traits (pharyngeal collapsibility and loop gain) as determinants of greater oral appliance efficacy.Objectives: We used a clinically applicable method to estimate OSA traits from routine polysomnography and identify an endotype-based subgroup of patients expected to show superior efficacy.Methods: In 93 patients (baseline apnea-hypopnea index [AHI], ≥20 events/h), we examined whether polysomnography-estimated OSA traits (pharyngeal: collapsibility and muscle compensation; nonpharyngeal: loop gain, arousal threshold, and ventilatory response to arousal) were associated with oral appliance efficacy (percentage reduction in AHI from baseline) and could predict responses to treatment. Multivariable regression (with interactions) defined endotype-based subgroups of "predicted" responders and nonresponders (based on 50% reduction in AHI). Treatment efficacy was compared between the predicted subgroups (with cross-validation).Results: Greater oral appliance efficacy was associated with favorable nonpharyngeal traits (lower loop gain, higher arousal threshold, and lower response to arousal), moderate (nonmild, nonsevere) pharyngeal collapsibility, and weaker muscle compensation (overall R2 = 0.30; adjusted R2 = 0.19; P = 0.003). Predicted responders (n = 54), compared with predicted nonresponders (n = 39), exhibited a greater reduction in AHI from baseline (mean [95% confidence interval], 73% [66-79] vs. 51% [38-61]; P < 0.0001) and a lower treatment AHI (8 [6-11] vs. 16 [12-20] events/h; P = 0.002). Differences persisted after adjusting for clinical covariates (including baseline AHI, body mass index, and neck circumference).Conclusions: Quantifying OSA traits using clinical polysomnography can identify an endotype-based subgroup of patients that is highly responsive to oral appliance therapy. Prospective validation is warranted.
Related Concept Videos
04:53Acupoint Application Combined with Ear Plaster Therapy for Treating Sleep Disorders with Acute Exacerbation of Chronic Obstructive Pulmonary Disease
04:33Association Between Sleep Quality and Cognitive Symptoms in Patients with Major Depressive Disorder
05:26Examination of Oral Candida Infection in Primary Sjögren's Syndrome Patients
07:40Multi-Modal Home Sleep Monitoring in Older Adults
07:54Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Sleep Apnea
The condition is more prevalent among...