Related Experiment Video
Updated: Jan 21, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Comparison of Totally Thoracoscopic and Traditional Sternotomy Approaches for Mitral Valve Replacement
He Fan1, Qian Xi Ming1, Zhang Wei Min1
1Department of Cardiac Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, China.
Background:
We aimed to investigate the feasibility and safety of mitral valve replacement using a totally thoracoscopic approach in comparison with traditional median sternotomy.
Methods:
Between January 2016 and December 2017, 94 consecutive patients who underwent mitral valve replacement were divided into two groups: A thoracoscopic group (43 cases) and a traditional group (51 cases). For the thoracoscopic group, all patients underwent total thoracoscopic procedures with femoral arterial and venous cannulation to cardiopulmonary bypass, transthoracic aortic cross-clamp, and antegrade cardioplegia. Three intercostal ports in the right chest were used for access in the thoracoscopic group. The operation was performed completely under two-dimensional video. For the traditional group, all operations were done with traditional median sternotomy.
Results:
All the operations were successfully performed. The thoracoscopic group had longer aortic cross-clamping and cardiopulmonary bypass times compared with the traditional group (62.30 ± 8.17 minutes versus 44.90 ± 12.00 minutes, P < .001; 92.33 ± 12.03 minutes versus 74.22 ± 14.72 minutes, P < .001). The two groups did not show statistically significant differences with respect to operative times (184.26 ± 32.49 minutes versus 181.47 ± 23.31 minutes, P = .631). In addition, the postoperative mechanical ventilation, ICU stay, and postoperative hospital stay times and postoperative drainage were 10.14 ± 2.21 hours and 11.35 ± 2.58 hours (P = .016), 21.40 ± 3.15 hours and 29.12 ± 6.59 hours (P < .001), 8.70 ± 2.52 days and 10.04 ± 3.11 days (P = .023), and 325.71 ± 97.11 mL and 396.57 ± 121.50 mL (P < .001), respectively. Major postoperative complications occurred in three (6.98%, P = .873) cases of the thoracoscopic group. Four (7.84%) cases of the traditional group had postoperative complications.
Conclusions:
Despite the disadvantages such as long cross-clamp and cardiopulmonary bypass times, totally thoracoscopic mitral valve replacement is feasible and safe. More importantly, one of the principal advantages with three intercostal ports over standard sternotomy is avoiding retrosternal adhesion, thus lowering the risk of needing to redo a cardiac procedure in the future.
More Related Videos
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Mitral Stenosis I: Introduction
Mitral Regurgitation I: Introduction
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...