Related Experiment Video
Updated: Jan 21, 2026

Point-of-Care Ultrasound: A Review of Ultrasound Parameters for Predicting Difficult Airways
Published on: April 7, 2023
Determination of physiotherapy ultrasound beam quality parameters from images derived using thermochromic material
Gordana Žauhar1, Ðeni Smilović Radojčić2, Zoran Kaliman3
1University of Rijeka, Faculty of Medicine, Department of Medical Physics and Biophysics, Braće Branchetta 20, 51 000 Rijeka, Croatia; University of Rijeka, Department of Physics, Radmile Matejčić 4, 51 000 Rijeka, Croatia.
Abstract:
The evaluation of the performance of nine physiotherapy ultrasound transducers used clinically was performed in the hospital environment using an acoustically absorbing thermocromic tile developed at the National Physical Laboratory (UK). The method consists of exposing an acoustic absorber tile, part of which contains a thermochromic pigment, to the ultrasonic beam, thereby forming an image of the intensity profile of the transducer. Images acquired using thermochromic materials were postprocessed in order to estimate effective radiating area (ERA) and beam nonuniformity ratio (BNR) for ultrasound transducers operating within the frequency range from 1.0 to 3.3 MHz, and nominal applied intensities in the range of 1-2W/cm2. Results of our measurements have shown that thermocromic tile can be used for quality control of ultrasound transducers in the hospital environment. Experimental results show that proposed method can be used to distinguish highly non - uniform ultrasound beams with high value of BNR. Influence of exposure duration on obtained ERA and BNR values was also analysed. Our results show that values for ERA increase with insonation time, while BNR values decrease. In order to compare our results with theory we have estimated temperature rise in thermochromic material experimentally and compare it with theoretical prediction.
More Related Videos
Related Concept Videos
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Wave Parameters