Related Experiment Video
Updated: Jan 21, 2026

Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
Mesh fixation in laparoscopic reconstruction of inguinal hernias
Introduction:
Laparoscopic inguinal hernia repair is a widely used surgical technique, although not exempt from potential complications. The aim of our study was to compare our postoperative results according to the fixation method of the prosthetic material.
Methods:
This is a retrospective study. We looked up 167 patients who underwent laparoscopic inguinal hernioplasty between 01 Jan 2015 and 31 Dec 2016 at the Surgical Department of Vsetin Hospital. The patients were invited for a follow-up visit after 46 weeks and a questionnaire was sent them after 933 months. We evaluated any development of postoperative hematoma, recurrent hernia and pain after one month and during the first year from the surgery in dependence on the fixation method (stapler Pro Thick, acrylic glue Glubran, 3D light mesh).
Results:
In total, 120 patients were enrolled in the study, 22 in the Glubran group, 59 in the stapler group and 39 in the 3D group. A hematoma developed in 10% in the stapler group, while there was none in the other groups; the difference was statistically significant (p=0.0382). Recurrent hernia was found in 5% in the Glubran group, 3% in the stapler group, and 0% in the 3D group; no statistically relevant difference was found. No difference was demonstrated for postoperative pain, either.
Conclusion:
Long-term postoperative results after TAPP were not found to differ in recurrence rates and pain based on the used fixation material in our set of patients. The stapler was associated with a higher risk of postoperative hematoma, but it was a preferred method in all cases of large hernias.
Related Concept Videos
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Carbon-dioxide Fixation
Reconstruction of Signal using Interpolation

