Related Experiment Video
Updated: Jan 21, 2026

A "Patient-Like" Orthotopic Syngeneic Mouse Model of Hepatocellular Carcinoma Metastasis
Published on: October 24, 2015
Value of Intravoxel Incoherent Motion for Hepatocellular Carcinoma Grading
Bedriye Koyuncu Sokmen1, Soheil Sabet1, Aysegül Oz1
1Department of Radiology, Istanbul Bilim University, Sisli Florence Nightingale Hospital, Istanbul, Turkey.
Background:
To evaluate the diagnostic accuracy of intravoxel incoherent motion (IVIM) parameters in estimation of hepatocellular carcinoma (HCC) grading.
Materials And Methods:
Twenty-nine patients with histopathologically diagnosed as 42 HCC at explant were included in this retrospective study. All patients were examined by 1.5T magnetic resonance imaging with the use of 4-channel phased array body coil. In addition to routine pre- and postcontrast sequences, IVIM (16 different b factors varying from 0 to 1300 s/mm2) and conventional diffusion-weighted imaging (3 different b factors of 50, 400, 800 s/mm2) were obtained with single-shot echo planar spin echo sequence. Apparent diffusion coefficient (ADC) and IVIM parameters including mean D (true diffusion coefficient), D* (pseudo-diffusion coefficient associated with blood flow), and f (perfusion fraction) values were calculated. Histopathologically, HCC was classified as low (grade 1, 2) and high (grade 3, 4) grade in accordance with the Edmondson-Steiner score. Quantitatively, ADC, D, D*, and f values were compared between the low- and high-grade groups by Student t test. The relationship between the parameters and histologic grade was analyzed using the Spearman's correlation test. To evaluate the diagnostic performance of the parameters, receiver operating characteristic analysis was performed.
Results:
High-grade HCCs had significantly lower ADC and D values than low grade groups (P = .005 and P = .026, retrospectively); ADC and D values were inversely correlated with tumor grade (r = -0.519, P = .011, r = -0.510, P = .026, respectively). High-grade HCCs had significantly higher f values when compared with the low-grade group (P = .005). The f values were positively correlated with tumor grade (r = 0.548, P = .007). The best discriminative parameter was f value. Cut-off value of 32% of f values showed sensitivity of 75.6% and a specificity of 73.5%.
Conclusion:
ADC values and IVIM parameters such as f values appear to reflect the grade of HCCs.
Related Concept Videos
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
Types of Aggregate Grading
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Sieve Analysis and Grading Curves
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Equation of Motion: General Plane motion - Problem Solving
The friction between the roller and the ground is characterized by two coefficients. The static friction coefficient is 0.15, while the kinetic friction coefficient is 0.1. These values are crucial in understanding the interaction between...

