Related Experiment Video
Updated: Jan 21, 2026

Versatile CO2 Transformations into Complex Products: A One-pot Two-step Strategy
Published on: November 9, 2019
Immobilization-free, split-mode cathodic photoelectrochemical strategy combined with cascaded amplification for
Fang Li1, Tianli Liu1, Hong Wang1
1International Joint Research Center for Photoresponsive Molecules and Materials, Key Laboratory of Synthetic and Biological Colloids (Ministry of Education), School of Chemical and Material Engineering, Jiangnan University, Wuxi, 214122, China.
Abstract:
We propose herein an immobilization-free, split-mode cathodic photoelectrochemical (PEC) strategy coupled with a cascaded amplification for versatile biosensing. Taking DNA and microRNA (miRNA) as the model targets, the hybridization between the targets and the hairpin probe triggers the digestion of the probe DNA by T7 exonuclease (T7 Exo), thus to generate G-quadruplex (G4) forming sequences, and then the released targets (DNA or miRNA) initiate the subsequent cycling processes and generate a large amount of G4 forming sequences. Subsequently, the formed G4 sequences associate with hemin to form the G4/hemin DNAzyme, which catalytically produces 1,4-bezoquinone (BQ) for conjugating onto the surface of the chitosan (CS) deposited BiOI/ITO photocathode via the quinone-chitosan conjugation chemistry (QCCC). Under photo excitation, the covalently attached quinones can act as electron acceptors of bismuth oxyiodine (BiOI), promoting the photocurrent generation and thus allowing the elegant and "signal-on" mode for probing targets of interest. Highly sensitive and selective PEC bioassays are readily realized, with the detection limits down to 2.2 fM (for DNA) and 0.2 fM (for miRNA). Since no labeling and no electrode modification processes are needed, this split-mode PEC biosensing strategy is amenable to convenient, time/labor saving, and high-throughput detections. More significantly, it provides a novel concept to design immobilization-free and label-free cathodic PEC biosensing systems, and showcases promise in general and versatile bioanalysis research.
Related Concept Videos
Intracellular Signaling Cascades
Rab Cascades
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
MAPK Signaling Cascades
Amplifying Signals via Enzymatic Cascade

