Related Experiment Video
Updated: Jan 21, 2026

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Magnetic resonance imaging texture analyses in lower-grade gliomas with a commercially available software:
Tokunori Kanazawa1, Yasuhiro Minami2, Hidenori Takahashi2
1Department of Neurosurgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Abstract:
Preoperative prediction of molecular information of lower-grade gliomas (LrGGs) helps to determine the overall treatment strategy as well as the initial surgical strategy. This study aimed to detect magnetic resonance imaging (MRI) texture parameters to predict the molecular signature of LrGGs using a commercially available software and routine MR images. Forty-three patients treated at Keio University Hospital who had World Health Organization grade II or III gliomas were included. All patients having preoperative T1- and T2-weighted, fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted (DW) images were also included. Texture analyses of T2, FLAIR, and apparent diffusion coefficient (ADC) histograms were performed using a commercially available software. Texture parameters including kurtosis, skewness, and entropy were investigated to determine any correlation with the presence or absence of isocitrate dehydrogenase (IDH) mutations, 1p/19q codeletion, and O6-methylguanine-DNA methyltransferase (MGMT) promoter methylation. ADC skewness and T2 skewness were significantly associated with 1p/19q codeletion status. ADC skewness of ≥ 0.25 predicted 1p/19q codeletion with a sensitivity and specificity of 80% and 65.2%, respectively (AUC = 0.728). T2 skewness of ≥ - 0.11 predicted 1p/19q codeletion with a sensitivity and specificity of 80% and 91.3%, respectively, (AUC = 0.866). None of the texture parameters were associated with IDH mutation and MGMT promoter methylation. MRI texture analysis using a commercially available software demonstrated that T2 skewness could predict 1p/19q codeletion with high sensitivity and specificity, suggesting a clinical utility.
Related Concept Videos
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the...
Magnetic Resonance Imaging
Calibration Curves: Correlation Coefficient
Calculating and Interpreting the Linear Correlation Coefficient
Imaging Studies IV: Magnetic Resonance Imaging
Skewness
The longer the tail of the plot on one side, the more skewed it is. The skewness of a data set’s values suggests that the measures of central tendency...

