Objectives:
To explore the feasibility of applying smart-planes fetal heart (S-Planes FH) to 3D volumes to generate and display the outflow tract views (OFTVs) and evaluate its agreement and reliability in determining fetal vessel dimensions.
Methods:
A total of 147 normal fetuses in the second or third trimester were enrolled. Once conventional 2D sonographic examination was finished, one or more 3D static volumes were then acquired in the 4-chamber view (4CV). The OFTVs automatically generated and displayed via a simple offline operation using S-Planes FH software. Per fetus, a single qualified S-Planes FH image was selected by an expert. The inner diameters of the aorta (AO) and pulmonary artery (PA) were measured in 2D and S-Planes FH images, respectively. The agreement and reliability of the two methods were verified by the Bland-Altman method and the intraclass correlation coefficient (ICC), respectively.
Results:
A total of 515 3D static volumes were successfully acquired in 147 fetuses. The OFTVs were generated and displayed using S-Planes FH in 138 (93.9%) cases. S-Planes FH had good agreement in measuring the diameters of great arteries (95% CI of limits, -0.9419 to 1.1464 for AO diameter, -0.8871 to 1.7007 for PA diameter). The intraobserver and interobserver ICCs in this study were greater than 0.81, indicating almost perfect reliability of the two methods with regard to observers.
Conclusions:
S-Planes FH software is a feasible method for generating OFTVs as well as determining vessel dimensions in the second and third trimesters and had good agreement with 2D examination. Therefore, it possesses clinical value in screening for CHD and can be operated by different sonographers.
Related Concept Videos
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Body Planes
The sagittal plane is the plane that divides the body or an organ vertically into right and left sides. If this vertical plane runs directly down the middle of the body resulting in equal division, it is called the midsagittal or median...
Transformation of Plane Stress
Plane Electromagnetic Waves I
The EM field is assumed to be a...
Plane Electromagnetic Waves II
Plane Potential Flows
Uniform...