Related Experiment Video
Updated: Jan 21, 2026

Cardiopulmonary Bypass in a Mouse Model: A Novel Approach
Published on: September 22, 2017
The influence of gaseous microemboli on various biomarkers after minimized cardiopulmonary bypass
Marco C Stehouwer1, Roel de Vroege2, Eline F Bruggemans3
1Department of Extracorporeal Circulation, St. Antonius Hospital, Nieuwegein, The Netherlands.
Introduction:
Gaseous microemboli that originate from the cardiopulmonary bypass circuit may contribute to adverse outcome after cardiac surgery. We prospectively evaluated the influence of gaseous microemboli on the release of various biomarkers after use of a minimally invasive extracorporeal technology system.
Methods:
In 70 patients undergoing coronary artery bypass grafting with minimized cardiopulmonary bypass, gaseous microemboli were measured intraoperatively with a bubble counter. Intra- and postoperative biomarker levels for inflammatory response (interleukin-6, C5b-9), endothelial damage (von Willebrand factor, soluble vascular cell adhesion molecule-1), oxidative stress (malondialdehyde, 8-isoprostane, neuroketal), and neurological injury (neuron-specific enolase, brain-type fatty acid-binding protein) were analyzed using immune assay techniques. The relationship between gaseous microemboli number or volume and the incremental area under the curve (iAUC24h) or peak change for the biomarkers was calculated.
Results:
All biomarkers except for malondialdehyde increased at least temporarily after coronary artery bypass grafting with a minimally invasive extracorporeal technology system. The median total gaseous microemboli number was 6,174 (interquartile range: 3,507-10,531) and the median total gaseous microemboli volume was 4.31 µL (interquartile range: 2.71-8.50). There were no significant correlations between total gaseous microemboli number or volume and iAUC24h or peak change for any of the biomarkers. After controlling for the variance of possible other predictor variables, multiple linear regression analysis showed no association between gaseous microemboli parameters and release of biomarkers.
Conclusion:
This study showed no evidence that gaseous microemboli contribute to increased biomarker levels after coronary artery bypass grafting with cardiopulmonary bypass. A reason for the absence of damage by gaseous microemboli may be the relative and considerably small amount of gaseous microemboli entering the patients in this study.
Related Concept Videos
Homogeneous Equilibria for Gaseous Reactions
For gas-phase reactions, the equilibrium constant may be expressed in terms of either the molar concentrations (Kc) or partial pressures (Kp) of the reactants and products. A relation between these two K values may be simply derived from the ideal gas equation and the definition of molarity. According to the ideal gas equation:
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves...
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation III: AED Use
Cardiopulmonary Resuscitation IV: Pharmacological Management
Cardiopulmonary Resuscitation II: ACLS Airway Management