Assessment of cochlear trauma and telemetry measures after cochlear implantation: A comparative study between
Domenico Cuda1, Alessandra Murri1
1Department of Otorhinolaryngology, Guglielmo da Saliceto Hospital, Piacenza, Italy.
Abstract:
The aim of this study was to compare the new Cochlear™ Nucleus® Profile with Slim Modiolar Electrode (CI532, Cochlear Ltd., Sidney, Australia) with the previous Contour Advance® (CI512) implant through postoperative residual hearing (RH) threshold shift and telemetry measurements as indirect measures of cochlear trauma. We compared 21 patients implanted with the CI532 and 20 patients implanted with the CI512, matching the 2 groups for age and for hearing loss etiology. All subjects received audiological pure tone average (PTA) calculation pre- and postimplant. Electrode impedance was measured, followed by AutoNRT® to measure and evaluate the Neural Response Telemetry (NRT®) thresholds. Telemetry recordings were made intraoperatively, one month after surgery and one month after activation. The NRT-Ratio was calculated to evaluate full scala tympani (ST) insertion. The results showed a higher number of patients with preserved measurable hearing with the CI532 (10/15; P>0.05) compared to the CI512 (5/14; P<0.05). A significant difference in post-operative low frequency PTA was observed between the two groups. There were no significant differences for telemetry measurements and NRTRatio evaluation of full ST insertion (CI512: 81%; CI532: 95%). A significantly higher number of patients who preserved measurable hearing with the CI532, and a significantly higher post-operative low frequency PTA threshold compared with the CI512 confirmed better RH preservation and lower apical cochlear damage with the CI532. There was a high number of full ST insertions for both electrode arrays. Future studies should investigate the audiological effect of implantation in patients with higher levels of RH, correlating the results with the scalar position, to assess any lesser trauma of the CI532.
More Related Videos
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
03:58Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Related Concept Videos
The Nucleus
Arrangement of DNA within Nucleus
The regulation of gene expression inside the nucleus is dependent on many factors, including the DNA structure. The...
The Nucleus
Arrangement of DNA within Nucleus
The regulation of gene expression inside the nucleus is dependent on many factors, including the DNA structure. The...
Standard Electrode Potentials
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Comparing the Survival Analysis of Two or More Groups