Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length
Laurence Shen Lim1,2, Xian Hui Lim1, Licia Tan1
1Singapore National Eye Centre, 11 Third Hospital Ave, Singapore 168751, Singapore.
Purpose:
To evaluate the relationships between refractive error, axial length (AL), and retinal vascular oxygen saturation in an adult population.
Methods:
This was a hospital-based, prospective observational study. The left eyes of phakic adult subjects without media opacity were analyzed. Subjective undilated manifest refraction was performed, and refractive errors were defined as myopia (spherical equivalent [SE], <-1 D), emmetropia (SE between -1 D and +1 D) and hyperopia (SE >+1 D). Retinal oximetry was performed using the Oxymap system (Oxymap Inc., Reykjavik, Iceland). Multivariate linear regression models were constructed to assess the relationship between retinal vascular oxygen saturation, SE, and AL obtained with optical biometry, with adjustments for age, sex, race, blood pressure, hyperlipidemia, and diabetes mellitus.
Results:
There were 85 subjects, with mean age of 66.1 ± 11.3 years. The majority were female (60%) and Chinese (84%). A total of 60% were myopic, 28% emmetropic, and 12% hyperopic. Mean SE was -5.29 ± 6.51 D and mean AL was 25.30 ± 2.99 mm. In multivariate analyses, more myopic SE and longer AL were associated with lower retinal arteriolar oxygen saturation (regression coefficient B = 0.61 [95% confidence interval, 0.28, 0.95], P = 0.001; and B = -1.13 [95% confidence interval, -1.71, -0.56], P < 0.001, respectively). Subjects with myopic SE and AL also had lower retinal arteriolar oxygen saturation than emmetropes and hyperopes (P = 0.03 and P = 0.02, respectively).
Conclusions:
Eyes with more myopic SE and longer AL have lower retinal arteriolar oxygen saturation.
Translational Relevance:
This study provides direct evidence of a link between retinal oxygenation and hypoxia and myopia by using a novel device that quantifies retinal vascular oxygenation in vivo.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Solution Equilibrium and Saturation
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Axial and Appendicular Muscles
Axial Muscles
Axial muscles, situated along the body's midline, are intricately connected to the axial skeleton, which includes the skull, spine, ribs, and sternum. These muscles facilitate facial expressions and...