Background:
Supplemental oxygen is a recommended therapy option in stable hypoxemic COPD patients. Often, supplemental oxygen is provided by continuous flow (CF). However, demand oxygen delivery systems (DODS) that provide an oxygen bolus only during inspiration have gained increasing use as they prolong oxygen cylinder life (beside battery life). However, there is a lack of evidence if different DODS and CF devices are equivalent.
Methods:
Seventy hypoxemic COPD patients (FEV1 32 ± 9% predicted, PaO2 56±7 mmHg) on long-term oxygen therapy were included in this prospective single-blinded, randomized cross-over trial. Following an initial incremental shuttle walk test, patients performed 3 endurance shuttle walk tests (ESWT) at 85% of their maximum walking speed in random order with: (A) CF (ESWT-CF), (B) a DODS based on liquid oxygen (ESWT-DL) and (C) an DODS oxygen concentrator (ESWT-DC). The primary outcome was oxygen saturation (SpO2) at ESWT isotime. Secondary outcomes were total ESWT duration, heart rate (HR) and breathing frequency (BF) at isotime and dyspnea at end-exercise.
Results:
SpO2 at ESWT isotime was not clinically different between devices: 90 ± 4% (CF), 89 ± 5% (DL) and 90 ± 5% (DC). However, 20% of the patients showed a ≥4% lower oxygen desaturation while using a DODS device. Secondary outcomes were similar under the three conditions.
Conclusion:
Oxygen supplementation via DODS (based on liquid oxygen or as a concentrator) yielded comparable physiological effects during standardized walking in stable hypoxemic COPD patients like CF. However, 20% of patients showed a clinically relevant lower oxygen saturation while using a DODS device. Therefore, we suggest individual testing of oxygen saturation of DODS suitability.
Related Concept Videos
Blind Procedures
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Blinding
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...