Related Experiment Video
Updated: Jan 21, 2026

05:07
Assessing the Particulate Matter Removal Abilities of Tree Leaves
Published on: October 7, 2018
7.2K
The Reliability of Using a Laser Device to Assess Deceleration Ability.
1Department of Sport, Health and Exercise Sciences, University of Hull, Hull HU6 7RX, UK.
Sports (Basel, Switzerland)
|August 14, 2019
Summary
This study found that a laser Doppler device offers moderate to excellent reliability in measuring deceleration ability in rugby players. This method shows promise for objectively quantifying this key component of athletic performance.
Area of Science:
- Sports Science
- Biomechanics
- Athletic Performance Analysis
Background:
- Deceleration ability is crucial for change of direction speed in athletes.
- Objective measurement methods for deceleration are scarce in existing literature.
- Quantifying deceleration is essential for training and performance evaluation.
Purpose of the Study:
- To assess the reliability of a laser Doppler device (LAVEG) for quantifying deceleration ability.
- To investigate both within- and between-session reliability metrics (ICC, CV, SEM, SDD).
- To evaluate the device's utility in amateur rugby union players.
Main Methods:
- Twenty amateur rugby union players participated in the study.
- Participants completed familiarization and two experimental sessions separated by seven days.
- Maximal 15m sprints followed by immediate deceleration to a stop were measured using a laser Doppler device.
- Deceleration was analyzed based on the distance to reach specific velocity percentages (75%, 50%, 25%, 0%).
Main Results:
- Within-session reliability was moderate to good (ICC: 0.64-0.83) with borderline acceptable variation (CV: 10.51%-16.71%).
- Between-session reliability demonstrated good to excellent relative reliability (ICC: 0.79-0.93).
- Acceptable absolute reliability was observed for stopping distance (SEM: 6.54%; SDD: 9.11%).
Conclusions:
- The laser Doppler device exhibits promising reliability for quantifying athlete deceleration ability.
- This objective method can be a valuable tool for sports science and coaching.
- Further research can explore its application across different sports and athlete populations.
Related Concept Videos
Reliability and Validity
13.7K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
13.7K
Distribution Reliability and Automation
498
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
498
Mnemonic Devices
404
Mnemonic devices are cognitive tools that facilitate memory retention by linking new information to familiar patterns or organizational strategies. These techniques are beneficial for remembering complex or lengthy sets of information by simplifying and structuring them in easily retrievable ways.
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
404
Non-ohmic Devices
1.5K
In most substances, the current flow is proportional to the voltage applied to it. A simple relationship between the values of current, voltage, and resistance is known as Ohm's law. Nonohmic devices do not exhibit a linear relationship between voltage and current. One such device is the semiconducting circuit element known as a diode. A diode is a circuit device that allows current flow in only one direction.
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
1.5K
Matrix-Assisted Laser Desorption Ionization (MALDI)
1.0K
Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
1.0K
Assessment of the Mouth
1.1K
A thorough mouth assessment, including inspection and palpation of the lips, gums, tongue, tonsils, uvula, and pharynx, is crucial in detecting potential health issues. Diseases ranging from oral cancer to systemic conditions like diabetes could be identified early through careful oral examination. This article provides a detailed guide on conducting a comprehensive mouth assessment.
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
1.1K

