The long term risk of lead failure in patients with cardiovascular implantable electronic devices undergoing catheter
Michal M Farkowski1, Aleksander Maciag1, Jan Ciszewski1
1Heart Arrhythmia Ward, II Department of Coronary Artery Disease, Institute of Cardiology, Warsaw, Poland.
Abstract:
Objectives. The aim of the study was to assess the long-term influence of catheter ablation (CA) of different arrhythmias on cardiovascular implantable electronic devices (CIED) endocardial leads durability. Design. This was a retrospective case-control study. Ablation protocols and in- or outpatient medical records were reviewed to identify and extract data on adult patients with CIED undergoing a CA. A cohort of patients with hypertrophic cardiomyopathy and implantable cardioverter-defibrillators (ICD) served as a historical control group. The primary endpoint was the diagnosis of lead damage defined as permanent loss of proper function demanding replacement or removal. Results. Among 145 patients n = 177 catheter ablations were performed. Patients' mean age was 66.4 ± 10.5, 66.1% had an ICD or ICD with cardiac resynchronization function (CRT-D), 18.1% had >1 CA. During median 812 days [IQR 381-1588] of follow-up, there were 11 (6.2%) cases of lead damage in the examined and 13 cases (13%) in the control group, p = 0.054. None of the technical aspects of the CA (indication, type of catheter, transseptal sheath) influenced the primary outcome. Both the number of leads and observation time after CA were significantly related to the risk of endocardial lead damage. Conclusion. This study did not find any significant influence of CA on the long-term durability of CIED endocardial leads. Reported risk factors were consistent with general population of CIED patients.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Relative Risk
Overview of the Cardiovascular System
Heart
The heart is the central pump of the cardiovascular system that circulates blood throughout the body. It comprises two atria receiving the blood and two ventricles pumping blood out of the heart. Their rhythmic contractions, called heartbeats, ensure that blood flow remains continuous.
Blood Vessels
Blood...
Electron Affinity
Long-term Depression
Regulation of the Cardiovascular System
The regulation of the cardiovascular system involves the autonomic nervous system (ANS), baroreceptors, and chemoreceptors, ensuring that heart rate and blood pressure are appropriately modulated in response to varying physiological demands.
The ANS comprises two main divisions: the sympathetic and parasympathetic nervous systems. The sympathetic nervous system enhances...