Related Experiment Video
Updated: Jan 20, 2026

Cardiopulmonary Bypass in a Mouse Model: A Novel Approach
Published on: September 22, 2017
Changes in nonlinear dynamic complexity measures of blood pressure during anesthesia for cardiac surgeries using
Valluvan Rangasamy1, Teresa S Henriques2, Pooja A Mathur1
1Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Abstract:
Nonlinear complexity measures computed from beat-to-beat arterial BP dynamics have shown associations with standard cardiac surgical risk indices. They reflect the physiological adaptability of a system and has been proposed as dynamical biomarkers of overall health status. We sought to determine the impact of anesthetic induction and cardiopulmonary bypass (CPB) upon the complexity measures computed from perioperative BP time series. In this prospective, observational study, 300 adult patients undergoing cardiac surgery were included. Perioperative period was divided as: (1) Preoperative (PreOp); (2) ORIS-induction to sternotomy; (3) ORSB- sternotomy to CPB; (4) ORposB-post CPB and within 30 min before leaving OR and (5) postoperative phase (PostOp)-initial 30 min in the cardiac surgical intensive care unit. BP waveforms for systolic (SAP), diastolic (DAP), mean arterial pressure (MAP) and pulse pressure (PP) were recorded, and their corresponding complexity index (MSE∑) was calculated. Significant decrease in MSE∑ from Preop to PostOp phases was observed for all BP time series. Maximum fall was seen during post anesthetic induction (ORIS) phase. Mild recovery during the subsequent phases was observed but they never reached the baseline values. In an exploratory analysis, preoperative MSE∑ showed a significant correlation with postoperative length of ICU stay. Blood pressure complexity varies at different time points and is not fixed for a given individual. Preoperative BP Complexity decreased significantly following anesthetic induction and did not recover to baseline until 30 min after surgery. Prevention of this significant fall may offer restoration of MSE∑ throughout surgery. Furthermore, preoperative BP complexity needs to be explored as a predictor of major postoperative adverse events by itself or in addition with the current risk indices.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer

