Related Experiment Video
Updated: Jan 20, 2026

Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Development of a contrast-enhanced micro computed tomography protocol for the oval squid (Sepioteuthis lessoniana)
1Department of Marine and Environmental Sciences, Graduate School of Engineering and Science, University of the Ryukyus, Okinawa, Japan.
Abstract:
Coleoid cephalopods (squid, cuttlefish, and octopus) have a well-developed and complex central nervous system. Its absolute size is the largest among invertebrates, and the brain-to-body mass ratio is larger than that of fish and reptiles and equivalent to that of birds and mammals. Although a number of histological studies have been conducted on the brains of cephalopods, most of them used a light microscope or an electron microscope, which show the microstructure of the brain, but often cannot image the whole brain instantaneously. Of late, micro computed tomography (CT) has gained popularity for imaging animal brains because it allows for noninvasive three-dimensional (3D) reconstruction and preprocessing that are not cumbersome. To perform micro-CT on cephalopod brains, we first tested conditions suitable for preprocessing, paying special attention to staining conditions that would provide high contrast images. Four agents, iodine in 99.5% ethanol, iodine potassium iodide in water (IKI), phosphotungstic acid in 70% ethanol, and nonionic iodinated contrast agent in water, were tested at various concentrations and durations on brain of juvenile oval squid. To evaluate the quality of staining, we calculated the contrast ratio of the two-dimensional (2D) images and compared 3D segmentation of the best and worst 2D images. We concluded that 3% IKI staining for 7 days was the best combination to enhance the images contrast of the oval squid brain, in which each brain lobe was clearly detected and 3D segmentation of the whole brain was possible. The wider applicability of this preprocessing method for micro-CT of the brains of other cephalopods is discussed.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement

