Semi-automated speckle-tracking for quantitative right ventricular assessment in children and adolescents
Aron K McCloud1,2, Joanna Lowisz1, David A Roberson1
1Division of Pediatric Cardiology, Advocate Children's Hospital, Oak Lawn, IL, USA.
Background:
Assessment of right ventricular size and function is an important part of the clinical cardiac evaluation; however, these quantitative measures are challenging by echocardiography. Automated software could be useful in place of manual measurements and qualitative assessment. This study evaluates a semi-automated software by comparing automated to manual measures in normal children.
Methods:
Neonates to adolescents with normal echocardiograms were prospectively enrolled. Measurements were performed using manual techniques and semi-automated software (EchoInsight®, Epsilon Imaging, Ann Arbor, Michigan, United States of America). Right ventricular measurements included end-diastolic and end-systolic area, fractional area change, chamber dimensions, and tricuspid annular plane systolic excursion. Agreement between manual and semi-automated measures was compared.
Results:
Echocardiograms for 233 patients were included in the analysis. Intra- and inter-observer reliabilities for semi-automated measures were good with intraclass correlation coefficients all over 0.9 and 0.85, respectively. There was very strong correlation between manual and semi-automated methods for areas and dimensions (r = 0.93-0.99) and low bias (1.4-10.8%). For functional measures, tricuspid annular plane systolic excursion measures correlated well (r = 0.84), but fractional area change did not (r = 0.50). Both demonstrated significant bias (33.5-43.0%). The semi-automated method consistently underestimated fractional area change with a mean of 26.6% versus a manual mean of 36.1%.
Conclusions:
The semi-automated software is capable of generating quantitative right ventricular measures in children with good reliability. The software demonstrates very good correlation and low bias when compared to manual methods for right ventricular areas and dimensions. There is a significant difference between manual and semi-automated techniques for the functional measures.
More Related Videos
05:10Author Spotlight: An Automated Method for Assessing Visual Acuity in Infants and Toddlers Using an Eye-Tracking System
Published on: March 17, 2023
08:52Psychophysical Tracking Method to Assess Taste Detection Thresholds in Children, Adolescents, and Adults: The Taste Detection Threshold TDT Test
Published on: April 21, 2021
Related Concept Videos
Cognitive Development During Adolescence
Revisionist Views of Adolescent and Adult Cognition
Erikson's Theory on Socioemotional Development during Adolescence
Drug Dosing: Infants and Children
Distribution Reliability and Automation
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...