Related Experiment Video
Updated: Jan 20, 2026

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Comparison of peripapillary and subfoveal choroidal thickness in normal versus primary open-angle glaucoma (POAG)
Swetha Komma1, Jay Chhablani2, Mohammed Hasnat Ali3
1VST Center for Glaucoma, L V Prasad Eye Institute, Hyderabad, India.
Objective:
To elucidate the difference between choroidal thickness (CT) in primary open-angle glaucoma (POAG) and normal subjects and to compare the CT measured using spectral domain optical coherence tomography (SD-OCT) and swept source optical coherence tomography (SS-OCT).
Methods And Analysis:
This cross-sectional observational study included 25 eyes of 17 POAG subjects (cases) and 31 eyes of 20 normal subjects (controls). All the patients underwent complete ophthalmologic examination, enhanced depth imaging, SD-OCT and SS-OCT. In both controls and cases, the CT was measured in seven predetermined points in macular and peripapillary area and were compared.
Results:
Choroid was significantly thicker on SS-OCT compared with SD-OCT in peripapillary and macular area in both cases and controls, except for inferior peripapillary in controls. The CT was not different from glaucoma and controls in peripapillary or macular area on SD-OCT (p>0.05), however, the CT was significantly thicker in glaucoma compared with controls in peripapillary area on SS-OCT (p<0.05) except inferior peripapillary (p=0.13). There was good intraobserver (±20 µm) and interobserver (±55 µm and ±45 µm) agreement on both SD-OCT and SS-OCT respectively.On SD-OCT, choroid was thinnest at the temporal peripapillary and thickest at subfoveal location in controls. In POAG, choroid was thinnest at inferior peripapillary region and thickest (500 µm) nasal to the fovea. On SS-OCT, choroid was thinnest at inferior peripapillary and thickest at the temporal peripapillary area in both cases and controls.
Conclusion:
CT measurements on SS-OCT were higher than the SD-OCT measurements possibly due to better delineation of the sclerochoroidal junction on SS-OCT. CT was significantly thicker in glaucoma subjects compared with controls in peripapillary area on SS-OCT but not in macular area.
More Related Videos
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Sources of Self-Esteem III: Social Comparison
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Properties of Enantiomers and Optical Activity