Cervical shear wave elastography as a predictor of preterm delivery during 18-24 weeks of pregnancy
Sasiwan Suthasmalee1, Sakita Moungmaithong1
1Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Aim:
The aim of this study was to compare shear wave cervical elasticity between term and preterm delivery group.
Methods:
A prospective cohort study was conducted in enrolled 158 pregnant women at 18-24 weeks of gestation who come for second trimester scan consecutively. Transvaginal ultrasonography for cervical length as well as cervical elasticity in five regions of interest was performed. Intraobserver and interobserver reproducibility were evaluated. Gestational age at deliveries was followed, and cervical shear wave elasticity between term and preterm group was compared.
Results:
A total of 158 pregnant women were enrolled in this study while 120 pregnancies data were collected for subsequent analysis, 10 pregnancies spontaneously delivered during the preterm period and 110 pregnancies delivered at term. Intraobserver and interobserver reproducibility were high; however, cervical shear wave elasticity in both groups were not significantly different (external anterior lip 2.29 ± 0.66 and 2.45 ± 0.58 m/s, P value 0.30, internal anterior lip 2.74 ± 0.96 and 2.80 ± 0.61 m/s, P value 0.83). Nonsignificant correlations of cervical shear wave elasticity with gestational age and cervical length (r = -0.1 and r = 0.02, respectively) were demonstrated.
Conclusion:
Cervical shear wave elasticity in preterm and term groups was not significantly different when measured at 18-24 weeks of gestation. There are nonsignificant correlations between cervical shear wave elasticity, gestational age and cervical length. Cervical shear wave elastography alone should not be used as a predictor for preterm delivery.
More Related Videos
14:43A Novel Method for Involving Women of Color at High Risk for Preterm Birth in Research Priority Setting
Published on: January 12, 2018
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
The Wave Nature of Light
Holter Monitor: 24-Hour Monitoring
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Half wave rectifier