Related Experiment Video
Updated: Jan 20, 2026

A Reference Broth Microdilution Method for Dalbavancin In Vitro Susceptibility Testing of Bacteria that Grow Aerobically
Published on: September 9, 2015
[Evaluation of the BD Phoenix100 System and Colistin Broth Disk Elution Method for Antimicrobial Susceptibility
Özlem Koyuncu Özyurt1, Betil Özhak1, Dilara Öğünç1
1Akdeniz University Faculty of Medicine, Department of Medical Microbiology, Antalya, Turkey.
Abstract:
Infections with multidrug resistant gram-negative bacteria is a growing problem especially in health care settings. Colistin is one of the last resort antibiotics for such infections in which treatment options are limited. Increasing resistance to colistin is a global problem. Clinical and Laboratory Standards Institute (CLSI) and the European Committee on Antimicrobial Susceptibility Testing (EUCAST) study groups have recommended the ISO-standard broth microdilution method (20776-1) as the reference method for the determination of colistin susceptibility. Since the broth microdilution method is not a practical method, it is rarely used in routine clinical microbiology laboratories, yet simple and accurate phenotypic detection methods for the determination of colistin resistance in routine microbiology laboratories are not precisely defined. The aim of this study was to evaluate BD Phoenix100 (Becton Dickinson, USA) system and colistin broth disk elution method for the detection of in vitro activity of colistin against gram-negative bacteria. A total of 419 gram-negative bacteria, including 199 Klebsiella pneumoniae, 163 Acinetobacter baumannii, 34 Escherichia coli, 20 Enterobacter spp., and three Citrobacter spp. isolates which were isolated from various clinical samples in our hospital between 2016-2018 were tested. The broth microdilution method was used as the reference method applying ISO-standard broth microdilution methods (20776-1) and CLSI/EUCAST recommendations. For colistin broth disk elution method, final concentrations of 0 (growth control), 1, 2 and 4 μg/ml were obtained by adding 10 μg colistin disks to four tubes containing 10 ml cation-adjusted Mueller Hinton broth per isolate. After incubation at room temperature for 30 minutes, 50 μl of standardized inoculum suspensions were added to the tubes. Colistin minimum inhibitor concentration (MIC) values were read visually after 16-20 hours of incubation at 35°C in ambient air. Manufacturer's recommendations were followed for BD Phoenix100 system. The categorical agreement between the reference broth microdilution method and the colistin broth disk elution method was 99.3%, very major error and major error rates were 0.2% and 0.5%, respectively. For BD Phoenix100 system, the categorical agreement was 95%, with a very major error rate of 5%. Our results showed that colistin broth disc elution method worked well compared to the reference broth microdilution method. The BD Phoenix100 system, with a high very major error rate, does not reliably distinguish colistin-resistant and colistin-susceptible strains.
More Related Videos
13:29Rapid Identification of Gram Negative Bacteria from Blood Culture Broth Using MALDI-TOF Mass Spectrometry
Published on: May 28, 2014
12:39Antimicrobial Susceptibility Testing of Mycobacterium Tuberculosis Complex for First and Second Line Drugs by Broth Dilution in a Microtiter Plate Format
Published on: June 24, 2011
Related Concept Videos
Gram-negative Bacterial Protein Secretion Systems
Faraday Disk Dynamo
Antimicrobial Effectiveness
Electric Field of a Charged Disk
The system's symmetry is in the cylindrical directions across the plane of the charge. As a result, the electric fields created by various surface charge elements nullify each other in the direction parallel to the surface. Thereby, the resulting electric field is perpendicular to the plane. Since the disk is...
High-Performance Liquid Chromatography: Elution Process
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...