Accelerated Tissue Processing With Minimal Formalin Fixation Time for 9-Gauge Vacuum-Assisted Breast Biopsy Specimens
Joris P Bulte1,2, Altuna Halilovic3, Lambert J M Burgers3
1Department of General Surgery, Radboud University Medical Center, Nijmegen, The Netherlands.
Objectives:
Vacuum-assisted biopsy (VAB) of the breast seems unsuitable for rapid processing due to large size. We tested microwave-based acceleration.
Methods:
As a proof-of-principle study, 9-gauge VAB specimens were taken from eight mastectomy specimens. Forty-two biopsy specimens were processed. Quality of H&E was evaluated in 84 slides, and estrogen receptor (ER), progesterone receptor (PR), E-cadherin, and human epidermal growth factor receptor 2 (HER2) stains were evaluated in six slides. Preoperative biopsy specimens were used as a control.
Results:
Diagnostic quality of H&E slides was good in 87%, reasonable in 12%, and low in 1%. Quality of E-cadherin was good in 75% and reasonable in 25%. Quality of ER was good in 83% and reasonable in 17%. PR and both HER2 immunohistochemistry and fluorescence in situ hybridization were good in all slides. Quality of experimental slides was similar to control slides.
Conclusions:
Nine-gauge VAB specimens can be processed within 4 hours. Slides are suitable for all routine pathologic stains. This enables a same-day diagnosis.
More Related Videos
10:10Long-term Culture of Human Breast Cancer Specimens and Their Analysis Using Optical Projection Tomography
Published on: July 29, 2011
06:42Optimization of Breast Biopsy and Mastectomy Sample Collection Procedures for Biobanking, Personalized Medicine, and Research Applications
Published on: September 2, 2025
Related Concept Videos
Pressure Gauges
Accelerators
The effectiveness of calcium chloride can...
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
Instantaneous Acceleration