A Porcine Corneal Endothelial Organ Culture Model Using Split Corneal Buttons
Published on: October 6, 2019
Diurnal Variation in Corneal Edema in Fuchs Endothelial Corneal Dystrophy
Marianne Fritz1, Viviane Grewing1, Philip Maier1
1Eye Center, University Medical Center Freiburg, Freiburg, Germany.
Purpose:
The extent of diurnal variation in corneal edema in Fuchs dystrophy is unknown. We measured corneal thickness and posterior profile over the course of the day using Scheimpflug imaging.
Design:
Prospective cohort study.
Methods:
Participants with clinically advanced Fuchs dystrophy eyes undergoing endothelial keratoplasty and participants with healthy corneas were assessed around noon the day before surgery and late afternoon, in presumed steady state. After controlled overnight patching to standardize eyelid closure, participants were assessed immediately upon eye opening in hospital the morning of surgery.
Results:
Directly upon awakening, patients had mean corneal thickness of 663 μm (interquartile range [IQR], 625-707) in Fuchs dystrophy (n = 44) and controls (n = 11) had thickness of 557 μm (IQR, 527-601). In control corneas, there were no systematic changes with time. In Fuchs dystrophy eyes, corneal thickness decreased after awakening. Ninety-five percent of patients can be expected to have a decrease in corneal thickness over the first 4 hours after awakening between 31 μm and 58 μm (95% prediction interval). Posterior Q decreased on average by 0.15 (95% confidence interval [CI], 0.07-0.23) and posterior radius of curvature decreased by 0.20 mm (95% CI, 0.14-0.27) over the first 4 hours, indicating that edema resolution steepened the central posterior cornea. Beyond 4 hours after awakening, corneas no longer changed considerably in Fuchs dystrophy.
Conclusion:
Impaired hydration control in clinically advanced Fuchs dystrophy makes measurements of key corneal parameters unreliable directly after eye opening. Beyond the first hours after eye opening, corneal thickness measurements are unlikely to vary more in Fuchs dystrophy eyes than in normal eyes.
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Coefficient of Variation
The coefficient of variation is a practical statistical tool in finance. It allows investors to assess the volatility or...