Related Experiment Video
Updated: Jan 20, 2026

In Vitro Assay to Evaluate the Impact of Immunoregulatory Pathways on HIV-specific CD4 T Cell Effector Function
Published on: October 15, 2013
Analytical performance evaluation and enhancement of the ADVIA Centaur® HIV Ag/Ab Combo assay
Baptiste Demey1, Cédric Usureau2, Paul Boillod3
1Department of Virology, Amiens University Medical Center, Amiens, France; AGIR Research Unit, EA 4294, Jules Verne University of Picardie, Amiens, France.
Background:
Fourth-generation immunoassays (such as the ADVIA Centaur® HIV Ag/Ab Combo (CHIV) assay) have improved the early diagnosis of human immunodeficiency virus (HIV), and their sensitivity and specificity usually exceed 99%. In regions with a low prevalence of HIV infection, however, the regular occurrence of false positives interferes with a medical laboratory's workflow. The additional reagent and staff costs associated with false positives can nevertheless be avoided or reduced by gaining a better knowledge of the CHIV assay's performance.
Objectives/Study Design:
To improve our HIV diagnosis strategy, we retrospectively analyzed all the Centaur® CHIV assays and confirmatory tests performed at Amiens University Medical Center between 2012 and 2018. We used open-source machine learning software to process this large database, develop a predictive model, and identify a new cut-off for Centaur® CHIV index interpretation.
Results:
A total of 56,682 HIV serological assay results were analyzed. The results of the CHIV assay were initially reactive or indeterminate for 449 samples. After p24 antigen and/or immunoblotting, there were 171 (38%) false positives and 278 (62%) confirmed true positives. The application of a cut-off of 2.12 led to reclassification of 130 of the 171 false positives as true negatives. Combining our predictive model with medical record analysis reduced the number of false positive CHIV assay results from 171 to 12.
Conclusions:
The efficiency of the Centaur® CHIV assay can be increased by adjusting its cut-off for positivity. This adjustment may reduce the number of unnecessary confirmatory tests and accelerate the delivery of HIV test results.
More Related Videos
13:58Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Published on: September 26, 2011
07:10Conformational Evaluation of HIV-1 Trimeric Envelope Glycoproteins Using a Cell-based ELISA Assay
Published on: September 14, 2014
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Development of Analytical Methods
Analyte Adsorption and Distribution
Jung's Analytical Theory
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
Bioavailability Enhancement: Drug Solubility Enhancement