Related Experiment Video
Updated: Jan 20, 2026

In Silico Clinical Trials for Cardiovascular Disease
Published on: May 27, 2022
Mismatch between sample diluent and eluent: Maintaining integrity of gradient peaks using in silico approaches
Fabrice Gritti1, Martin Gilar1, Jason Hill1
1Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.
Abstract:
The mismatch of elution strength between the sample diluent and the eluent causes undesirable peak deformations for large sample volumes in gradient liquid chromatography. The solution to that problem consists in diluting the sample solution in a weak solvent. But the minimum dilution factor has to be determined by the user given some performance objectives. In silico approaches are applied in this work to find such adequate dilution factors. Two calculations methods are proposed for the prediction of peak distortions. The first comprehensive method is based on solving numerically the mass balance equations for all the analytes and the strong solvent. An excellent agreement between the experimental and the calculated gradient chromatograms is observed (sample diluent: acetonitrile/water, 50/50, v/v; injection volume: 15 μL; linear gradient: 5%-95% acetonitrile during 3 min) for five compounds (acetanilide, coumarin, benzoin, bi-naphthol, and dibutylphthalate) injected into a 2.1 × 50 mm column packed with 1.7 μm XBridge-C18 particles. This first method happens to be highly time-consuming and impractical for common users. Experimental work and calculation times are then minimized by applying a second method based on the basics of retention and dispersion of injected pulses. Despite being less accurate than the first method, the agreement between the experimental and calculated peak width remains physically meaningful allowing the experimenter to rapidly guess the required sample dilution factor for any combination of injected volume and strong solvent concentration in the sample solution.
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
IR Spectrum Peak Broadening: Hydrogen Bonding
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular...