Related Experiment Video
Updated: Jan 20, 2026

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Unmixing multi-spectral photoacoustic sources in human carotid plaques using non-negative independent component
M U Arabul1, M C M Rutten1, P Bruneval2
1Biomedical Engineering, Eindhoven University of Technology, 5612 AJ Eindhoven, The Netherlands.
Abstract:
Multi-spectral photoacoustic imaging (MSPAI) is promising for morphology assessment of carotid plaques; however, obtaining unique spectral characteristics of chromophores is cumbersome. We used MSPAI and non-negative independent component analysis (ICA) to unmix distinct signal sources in human carotid plaques blindly. The feasibility of the method was demonstrated on a plaque phantom with hemorrhage and cholesterol inclusions, and plaque endarterectomy samples ex vivo. Furthermore, the results were verified with histology using Masson's trichrome staining. Results showed that ICA could separate recent hemorrhages from old hemorrhages. Additionally, the signatures of cholesterol inclusion were also captured for the phantom experiment. Artifacts were successfully removed from signal sources. Histologic examinations showed high resemblance with the unmixed components and confirmed the morphologic distinction between recent and mature hemorrhages. In future pre-clinical studies, unmixing could be used for morphology assessment of intact human plaque samples.
More Related Videos
Related Concept Videos
Independent and Dependent Sources
Independent voltage or current sources supply a fixed amount of voltage or current, respectively, which is unaffected by other elements within the circuit. These are represented using specific symbols. Independent voltage sources are symbolized with polarities (+ and -), indicating the direction of the...
Introduction to Test of Independence
The test statistic for a test of independence is similar to that of a goodness-of-fit test:
Hypothesis Test for Test of Independence
H0: The two variables (factors)...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...

