Related Experiment Video
Updated: Jan 20, 2026

Solid-state Graft Copolymer Electrolytes for Lithium Battery Applications
Published on: August 12, 2013
Solid phase extraction and capillary electrophoretic separation of racemic catecholamines by using magnetic particles
Jia Wu1, Zhenqun Li1, Li Jia2
1Ministry of Education Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
Abstract:
A method is presented for chiral separation of catecholamines present in bovine and mice blood. It combines magnetic solid phase extraction (MSPE) and chiral capillary electrophoresis (ch-CE). A copolymer consisting of poly(3,4-dihydroxyphenylalanine) and polyethyleneimine was coated onto magnetic particles (MPs) by co-deposition using the CuSO4/H2O2 system as a polymerization initiator. The coated MPs are spherical and the average diameter is about 168 ± 4 nm. The thickness of the coating is approximately 19 nm. The functional MPs are used as sorbents in MSPE to simultaneously extract the catecholamines epinephrine, norepinephrine and isoprenaline. Under the optimum conditions, the extraction efficiencies for those catecholamines are in the range from 92.3 to 98.3%, with relative standard deviations (RSDs) of <5.3%. The extraction can be performed within 4 min. The extracts were then submitted to ch-CE. A method for field-enhanced sample injection (FESI) was used to enhance the detection sensitivities of the enantiomers. The limits of detection for catecholamine enantiomers range from 400 to 600 pg mL-1. In comparison with the FESI-ch-CE method, the sensitivity enhancement factors of the MSPE/ch-CE method for catecholamines are about 10-fold. The method was applied to the determination of trace levels of catecholamine enantiomers in (spiked) bovine and mice blood. The recoveries ranged from 88.2 to 93.8%, with RSDs of <5.5%. The whole detection procedure takes less than 30 min. Graphical abstract Schematic representation of the separation and detection of catecholamine enantiomers in blood by combination of polyDOPA/PEI-magnetic particles-based solid phase extraction and chiral-capillary electrophoresis.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:35DNA-magnetic Particle Binding Analysis by Dynamic and Electrophoretic Light Scattering
Published on: November 9, 2017
Related Concept Videos
Structures of Solids
Phase Diagrams
Phase Transitions: Melting and Freezing
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Racemic Mixtures and the Resolution of Enantiomers
Motion Of A Charged Particle In A Magnetic Field