Holmium:Yttrium-Aluminum-Garnet Laser Pulse Type Affects Irrigation Temperatures in a Benchtop Ureteral Model
Brenton Winship1, Russell Terry1, Kohldon Boydston1
1Division of Urologic Surgery, Duke University Medical Center, Durham, North Carolina.
Abstract:
MOSES™ technology is a holmium:yttrium-aluminum-garnet laser pulse mode shown to minimize stone retropulsion. This may facilitate lithotripsy at higher power settings. However, power and heat production are proportional, and temperatures capable of tissue injury may occur during ureteroscopic lithotripsy. Although previous in vitro studies demonstrate the importance of irrigation and activation time on heat production, the impact of pulse type has not been evaluated. A flexible ureteroscope with a 365 μm laser fiber was placed in an 11/13 F access sheath inserted into a 50 mL saline bag to simulate a ureter, renal pelvis, and antegrade irrigant flow. A thermocouple was placed adjacent to the laser tip, and the laser fired for 30 seconds at 0.6 J/6 Hz, 0.8 J/8 Hz, 1 J/10 Hz, 1 J/20 Hz, and 0.2 J/70 Hz at irrigation pressure of 100 mmHg. Four runs were tested per setting using short pulse, long pulse (LP), MOSES-contact (MC), and MOSES-distance (MD) modes. The mean temperature changes (dT) were compared and thermal dose was calculated in cumulative equivalent minutes at 43°C (CEM43) using an adjusted baseline of 37°C. CEM43 ≥ 120 minutes was considered the tissue injury threshold. At 0.8 J/8 Hz, LP produced the greatest dT, significantly higher than MC (p = 0.041). CEM43 did not exceed the injury threshold. At 1 J/10 Hz, dT was significantly higher for LP versus MC and MD (p = 0.024 and 0.045, respectively). Thermal dose remained below the injury threshold. No differences in dT were seen between pulse types at 0.6 J/6 Hz, 0.2 J/70 Hz, or 1 J/20 Hz. At 1 J/20 Hz, thermal dose exceeded the injury threshold for all pulse types within 3 seconds. Laser pulse type and length seemed to impact heat production in our ureteral model. LP produced significantly greater temperatures at 0.8 J/8 Hz and 1 J/10 Hz relative to MOSES settings. Fortunately, thermal dose remained safe at these settings. Both LP and MOSES technology have been shown to reduce stone retropulsion. At power ≤10 W, the latter may confer this advantage with decreased heat production.
Related Concept Videos
Design Example: Design of an Irrigation Channel
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Regulation of Pulse