Related Experiment Video
Updated: Jan 20, 2026

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Optical sectioning and high resolution visualization of trabecular meshwork using Bessel beam assisted light sheet
C S Suchand Sandeep1, Sreelatha Sarangapani2, Xun J J Hong2
1Singapore Centre for 3D Printing, School of Mechanical & Aerospace Engineering, Nanyang Technological University, Singapore.
Researchers developed a new microscopy technique to image the trabecular meshwork, crucial for understanding glaucoma. This method provides high-resolution, 3D views of the eye's aqueous humor outflow system without dissection.
Area of Science:
- Ophthalmology
- Biomedical Optics
- Microscopy
Background:
- Glaucoma is a leading cause of blindness, characterized by elevated intraocular pressure due to aqueous humor outflow system dysfunction.
- High-resolution imaging of the trabecular meshwork is vital for glaucoma diagnosis and treatment but is limited by current ocular imaging technologies.
Discussion:
- A novel Bessel-Gauss beam scanned light sheet fluorescence microscopy technique achieves sub-micrometer resolution for trabecular meshwork imaging.
- This method enables non-invasive, three-dimensional volumetric imaging of the trabecular meshwork in intact eyes, overcoming limitations of existing devices.
Key Insights:
- Demonstrates optical sectioning capability for detailed 3D visualization of the trabecular meshwork.
- Presents a significant advancement in imaging technology for ocular research and clinical applications.
- Provides unprecedented detail of the aqueous humor outflow pathway.
Outlook:
- Potential to improve early glaucoma detection and monitoring.
- Facilitates deeper understanding of glaucoma pathophysiology.
- Opens new avenues for developing targeted glaucoma therapies.
Related Concept Videos
Super-resolution Fluorescence Microscopy
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Confocal Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Cross-Sectional Research
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation: