Lower Phase Angle Measured by Bioelectrical Impedance Analysis Is a Marker for Increased Mortality in Incident

Rong Huang1, Meiju Wu2, Haishan Wu2

  • 1Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China; Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China; Department of Nephrology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.

Abstract

Related Concept Videos

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
590
Peritoneal Dialysis I: Introduction and Procedure01:30

Peritoneal Dialysis I: Introduction and Procedure

Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
2.6K
Peritoneal Dialysis III: Nursing Management01:25

Peritoneal Dialysis III: Nursing Management

Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
702
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
427
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis01:30

Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis

Patients with end-stage renal disease (ESRD) or those experiencing drug overdose often require extracorporeal methods to eliminate accumulated drugs and metabolites. Hemoperfusion, hemofiltration, and dialysis are the primary techniques to rapidly remove harmful substances without disrupting the patient's fluid and electrolyte balance. For those with compromised renal function, dosage adjustments of concurrent medications may be necessary during extracorporeal drug removal.Dialysis is a process...
428
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
1.7K