Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Lower Phase Angle Measured by Bioelectrical Impedance Analysis Is a Marker for Increased Mortality in Incident
Rong Huang1, Meiju Wu2, Haishan Wu2
1Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China; Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, Guangdong, China; Department of Nephrology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.
Objective:
Phase angle (PA) determined by bioelectrical impedance analysis has been suggested to be a predictor of death in a variety of disease conditions, but its associations with outcomes have not yet been assessed in a large continuous ambulatory peritoneal dialysis (CAPD) patient cohort. The aim of the present study was to examine the association of PA with risks for all-cause and cardiovascular death in patients treated with CAPD.
Methods:
Incident CAPD patients were enrolled from January 1, 2010 to December 31, 2015 and were followed until December 31, 2017. Multifrequency bioelectrical impedance analysis was conducted in the morning with patients in a fasting state. Multivariable linear regression analyses were performed to study the relationships between PA and other variables. Cox proportional hazard models were used to evaluate the association between PA and mortality.
Results:
A total of 760 incident CAPD patients were enrolled in this study. Patients have a median PA value of 4.59° ranging from 2.30° to 7.22°. Aging, presence of diabetes mellitus, and fluid overload were independently associated with lower PA, whereas male sex, higher body mass index, higher serum levels of albumin and creatinine, and better residual renal function were independently associated with higher PA in a multivariable linear regression model. A total of 125 (16.4%) patients died during a median follow-up of 42 months. In the Cox model with adjustment for confounders, PA was significantly associated with all-cause and cardiovascular mortality in incident CAPD patients (hazard ratio, 0.584; 95% confidence interval, 0.403 to 0.844, P = .004; hazard ratio, 0.597; 95% confidence interval, 0.359 to 0.993, P = .047, respectively).
Conclusions:
PA reflected a combined dimension of the illness including deranged hydration status and nutritional status. Lower PA was associated with both all-cause and cardiovascular death in patients with CAPD.
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis III: Nursing Management
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Dialysis