Related Experiment Video
Updated: Jan 20, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
18F-Choline PET/mpMRI for Detection of Clinically Significant Prostate Cancer: Part 1. Improved Risk Stratification
Matthew S Davenport1,2, Jeffrey S Montgomery2, Lakshmi Priya Kunju3
1Radiology Department, University of Michigan, Ann Arbor, Michigan.
Abstract:
A prospective single-arm clinical trial was conducted to determine whether 18F-choline PET/mpMRI can improve the specificity of multiparametric MRI (mpMRI) of the prostate for Gleason ≥ 3+4 prostate cancer. Methods: Before targeted and systematic prostate biopsy, mpMRI and 18F-choline PET/CT were performed on 56 evaluable subjects with 90 Likert score 3-5 mpMRI target lesions, using a 18F-choline target-to-background ratio of greater than 1.58 to indicate a positive 18F-choline result. Prostate biopsies were performed after registration of real-time transrectal ultrasound with T2-weighted MRI. A mixed-effects logistic regression was applied to measure the performance of mpMRI (based on prospective Likert and retrospective Prostate Imaging Reporting and Data System, version 2 [PI-RADS], scores) compared with 18F-choline PET/mpMRI to detect Gleason ≥ 3+4 cancer. Results: The per-lesion accuracy of systematic plus targeted biopsy for mpMRI alone was 67.8% (area under receiver-operating-characteristic curve [AUC], 0.73) for Likert 4-5 and 70.0% (AUC, 0.76) for PI-RADS 3-5. Several PET/MRI models incorporating 18F-choline with mpMRI data were investigated. The most promising model selected all high-risk disease on mpMRI (Likert 5 or PI-RADS 5) plus low- and intermediate-risk disease (Likert 4 or PI-RADS 3-4), with an elevated 18F-choline target-to-background ratio greater than 1.58 as positive for significant cancer. Using this approach, the accuracy on a per-lesion basis significantly improved to 88.9% for Likert (AUC, 0.90; P < 0.001) and 91.1% for PI-RADS (AUC, 0.92; P < 0.001). On a per-patient basis, the accuracy improved to 92.9% for Likert (AUC, 0.93; P < 0.001) and to 91.1% for PI-RADS (AUC, 0.91; P = 0.009). Conclusion:18F-choline PET/mpMRI improved the identification of Gleason ≥ 3+4 prostate cancer compared with mpMRI, with the principal effect being improved risk stratification of intermediate-risk mpMRI lesions.
Related Concept Videos
Relative Risk
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Clinical Trials
There are four phases in a clinical trial. A phase one...
Improving Translational Accuracy