[Biomechanical changes of sheep cervical spine after unilateral hemilaminectomy and different degrees of facetectomy]
Related Experiment Video
Updated: Jan 20, 2026

A Contusive Model of Unilateral Cervical Spinal Cord Injury Using the Infinite Horizon Impactor
Published on: July 24, 2012
1Department of Neurosurgery, Peking University Third Hospital, Beijing 100191, China.
Objective:
To establish animal models and investigate the impact of unilateral hemilaminectomy (ULHL) and different degrees of facetectomy (FT) on the cervical spinal biomechanics.
Methods:
Twenty sheep were randomly and evenly divided into 4 groups. No operation was performed for group A, right C4-C6 ULHL was performed for group B, right C4-C6 ULHL and 50% ipsilateral C4-C5 FT was performed for group C, right C4-C6 ULHL and 100% ipsilateral C4-C5 FT was performed for group D. Animals of group A, B, C and D were sacrificed 24 weeks after operating and fresh cervical spine specimens were acquired, biomechanically tested and these data were compared to determine whether ULHL and different degrees of FT led to long-term differences in range of motion.
Results:
(1) Changes of the total range of motion of cervical spine 24 weeks after surgery: the total range of motion of group D (60.2°±8.6°) was significantly greater than group A (40.7°±6.4°) and group B (41.2°±13.1°) under flexion-extension station, the total range of motion of group D (81.5°±15.7°) was significantly greater than that of group A (56.7°±12.2°) and group B (57.7°±12.8°) under lateral bending station, and the total range of motion of group D (38.5°±17.5°) had no obvious increase compared with group A (26.4°±9.9°) and group B (27.1°±10.9°) under axial rotation station. The total range of motion of group C had no obvious increase compared with group A and group B under flexion-extension station (44.1°±11.7°), lateral bending station (73.6°±11.4°) and axial rotation station (31.3°±11.5°). (2) Changes of the intersegmental motion 24 weeks after surgery: the intersegmental motion of group D (20.3°±4.6°) at C4-C5 was significantly greater than that of group A (11.7°±3.4°) and group B (11.9°±2.1°) under flexion-extension station, the intersegmental motion of group D (26.8°±3.5°) at C4-C5 was significantly greater than that of group A (15.2°±3.1°) and group B (16.2°±3.2°) under lateral bending station, the intersegmental motion of group D (15.2°±3.5°) at C4-C5 was significantly greater than that of group A (6.6°±2.3°) and group B (7.1°±1.9°) under axial rotation station. The intersegmental motion of group C (21.2°±4.1°) at C4-C5 was significantly greater than that of group A and group B under lateral bending station, the intersegmental motion of group C at C4-C5 had no obvious increase compared with group A and group B under flexion-extension station (15.7°±3.7°) and axial rotation station (10.3°±3.1°).
Conclusion:
ULHL does not affect cervical stability, ULHL and 50% ipsilateral FT does not affect the long-term cervical stability, ULHL and 100% ipsilateral FT can lead to long-term instability under lateral bending and flexion-extension station.
Related Concept Videos
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...
Degree of Unsaturation
The degree of unsaturation for hydrocarbons is U = (2C + 2 − H) / 2, where C is the number of carbon atoms and H is the number of hydrogen atoms.
Cloning of Dolly the Sheep
Degree of Curvature and Radius of Curvature