Routine coagulation testing in Vacutainer® Citrate Plus tubes filled at minimum or optimal volume.
Fiamma Balboni1, Stefania Barbui2, Marco Gallo3
1Service of Laboratory Medicine, Istituto Fiorentino Cura e Assistenza (IFCA), Florence, Italy.
Diagnosis (Berlin, Germany)
|August 18, 2019
Summary
Filling citrate tubes at minimum volume does not clinically affect routine coagulation tests. Prothrombin time and fibrinogen showed slight decreases, while activated partial thromboplastin time remained statistically insignificant, ensuring reliable results.
Area of Science:
- Clinical Chemistry
- Hematology
- Diagnostic Testing
Background:
- Accurate blood volume in citrate tubes is critical for reliable coagulation test results.
- Variations in fill volume can potentially impact test accuracy.
- The new Becton Dickinson Vacutainer® Citrate Plus tubes require evaluation for fill volume impact.
Purpose of the Study:
- To assess if routine coagulation test results differ between minimum and optimal fill volumes in Vacutainer® Citrate Plus tubes.
- To determine the clinical comparability of coagulation testing using the new citrate tubes at varying fill levels.
- To validate the performance of Vacutainer® Citrate Plus tubes under different blood collection scenarios.
Main Methods:
- 133 patients (40 on oral anticoagulant therapy) had blood collected into two sequential Vacutainer® Citrate Plus tubes.
- Tubes were filled at minimum (aspirating air first) and optimal volumes.
- Experiments were conducted using both 2.7-mL and 1.8-mL tube sizes.
Main Results:
- Prothrombin time (PT) and fibrinogen levels were slightly decreased with minimum fill volume compared to optimal.
- Activated partial thromboplastin time (APTT) showed a slight, non-statistically significant prolongation at minimum fill.
- Correlations between fill volumes exceeded 0.94, with bias within quality specifications for both tube sizes.
Conclusions:
- Blood collection into Vacutainer® Citrate Plus tubes at minimum fill volume does not introduce clinically significant bias.
- Routine coagulation testing results remain reliable even with minimum fill volumes.
- The new Vacutainer® Citrate Plus tubes demonstrate acceptable performance across tested fill volumes.
Related Concept Videos
Coagulation
1.3K
Colloidal solids are solid particles suspended in solution. They are usually negatively charged, attracting a compact primary layer of positively charged ions, which attract more counterions to form an electrical double layer. Electrostatic repulsion between the charged double layers prevents the particles from colliding, stabilizing the colloids. These solids are often undesirable because they can contain toxins that are difficult to remove. Coagulation is a technique that helps aggregate and...
1.3K
Coagulation
9.7K
The coagulation phase is a critical part of the body's process to prevent blood loss following injury to blood vessels. It involves chemical reactions that form a clot to seal the injured area. The clotting process begins shortly after injury, within 15-20 seconds for severe damage and 1-2 minutes for minor injuries.
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
9.7K
Constant Volume Calorimetry
30.6K
Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.6K
Uterine Tubes
2.1K
The uterine or fallopian tubes function as the conduit through which oocytes travel from the ovaries to the uterus. Each fallopian tube measures approximately 10 to 13 cm long and is anatomically divided into the infundibulum, ampulla, isthmus, and interstitial part (or intramural segment). The infundibulum is characterized by its funnel shape and features extensions called fimbriae which reach towards the peritoneal cavity. These fimbriae play a critical role during ovulation as they extend...
2.1K
Endotracheal Tube Extubation
3.8K
Endotracheal tube extubation is a critical procedure in weaning patients from mechanical ventilation. It involves physically removing the oral or nasal endotracheal (ET) tube, marking the final step in liberating a patient from ventilatory support.
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
3.8K
Optimal Foraging
13.7K
How animals obtain and eat their food is called foraging behavior. Foraging can include searching for plants and hunting for prey and depends on the species and environment.
13.7K