Related Experiment Video
Updated: Jan 20, 2026

Comprehensive Autopsy Program for Individuals with Multiple Sclerosis
Published on: July 19, 2019
MRI quality control for the Italian Neuroimaging Network Initiative: moving towards big data in multiple sclerosis
Loredana Storelli1,2, Maria A Rocca1,3, Patrizia Pantano4,5
1Neuroimaging Research Unit, Institute of Experimental Neurology, Division of Neuroscience, IRCCS San Raffaele Scientific Institute, Via Olgettina, 60, 20132, Milan, Italy.
Abstract:
The Italian Neuroimaging Network Initiative (INNI) supports the creation of a repository, where MRI, clinical, and neuropsychological data from multiple sclerosis (MS) patients and healthy controls are collected from Italian Research Centers with internationally recognized expertise in MRI applied to MS. However, multicenter MRI data integration needs standardization and quality control (QC). This study aimed to implement quantitative measures for characterizing the standardization and quality of MRI collected within INNI. MRI scans of 423 MS patients, including 3D T1- and T2-weighted, were obtained from INNI repository (from Centers A, B, C, and D). QC measures were implemented to characterize: (1) head positioning relative to the magnet isocenter; (2) intensity inhomogeneity; (3) relative image contrast between brain tissues; and (4) image artefacts. Centers A and D showed the most accurate subject positioning within the MR scanner (median z-offsets = - 2.6 ± 1.7 cm and - 1.1 ± 2 cm). A low, but significantly different, intensity inhomogeneity on 3D T1-weighted MRI was found between all centers (p < 0.05), except for Centers A and C that showed comparable image bias fields. Center D showed the highest relative contrast between gray and normal appearing white matter (NAWM) on 3D T1-weighed MRI (0.63 ± 0.04), while Center B showed the highest relative contrast between NAWM and MS lesions on FLAIR (0.21 ± 0.06). Image artefacts were mainly due to brain movement (60%) and ghosting (35%). The implemented QC procedure ensured systematic data quality assessment within INNI, thus making available a huge amount of high-quality MRI to better investigate pathophysiological substrates and validate novel MRI biomarkers in MS.
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...

