Related Experiment Video
Updated: Jan 20, 2026

A Simple and Scalable Fabrication Method for Organic Electronic Devices on Textiles
Published on: March 13, 2017
All-Textile Electronic Skin Enabled by Highly Elastic Spacer Fabric and Conductive Fibers
Ronghui Wu1,2,3, Liyun Ma1,2, Aniruddha Patil1
1Research Institution for Biomimetics and Soft Matter, Fujian Provincial Key Laboratory for Soft Functional Materials Research, College of Physical Science and Technology, Jiujiang Research Institute , Xiamen University , Xiamen 361005 , China.
Abstract:
Electronic fabrics that combine traditional fabric with intelligent functionalities have attracted increasing attention. Here an all-fabric pressure sensor with a wireless battery-free monitoring system was successfully fabricated, where a 3D penetrated fabric sandwiched between two highly conductive fabric electrodes acts as a dielectric layer. Thanks to the good elastic recovery of the spacer fabric, the capacitance pressure sensor exhibits a high sensitivity of 0.283 KPa-1 with a fast response time and good cycling stability (≥20 000). Water-soluble poly(vinyl alcohol) template-assisted silver nanofibers were constructed on the high-roughness fabric surface to achieve high conductivity (0.33 Ω/sq), remarkable mechanical robustness, and good biocompatibility with human skin. In addition, the coplanar fabric sensor arrays were successfully designed and fabricated to spatially map resolved pressure information. More importantly, the gas-permeable fabrics can be stuck on the skin for wireless real-time pressure detection through a fiber inductor coil with a resonant frequency shift sensitivity of 6.8 MHz/kPa. Our all-fabric sensor is more suitable for textile technology compared with traditional pressure sensors and exhibited wide potential applications in the field of intelligent fabric for electronic skin.
Related Concept Videos
Elasticity
The elasticity of an object can be described by a stress-strain curve, which represents the relationship between stress...
Elasticity in Concrete
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...

