Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Corneal Biomechanical Evaluation After Conventional Corneal Crosslinking With Oxygen Enrichment
Jia Wang1, Lijun Wang, Zhiwei Li
1Department of Ophthalmology (J.W., L.W., Z.L., K.Z., G.M.), Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong, China; Aier Eye Hospital Group (J.W.), Liaocheng Aier Eye Hospital, Liaocheng, Shandong, China; Department of Ophthalmology (L.W.), Binzhou Medical University Hospital, Binzhou, Shandong, China; and Department of Ophthalmology and Visual Sciences (Y.M.W.), The Chinese University of Hong Kong, Hong Kong, China.
Purpose:
To assess corneal biomechanical changes after conventional corneal crosslinking (CXL), with and without oxygen enrichment.
Methods:
Sixty fresh porcine corneas were randomly divided into group 1 (control), group 2 (conventional CXL), and group 3 (conventional CXL in a high-oxygen environment during ultraviolet A [UVA] irradiation). After crosslinking, a 5-mm wide corneal strip was extracted using a double-bladed knife from 12 to 6'o clock. The Young's modulus of each strip was determined by stress-strain measurements. A comparison between the three groups was performed with a one-way analysis of variance.
Results:
At 4% strain, the Young's modulus of the corneas in groups 1, 2, and 3 were: 0.68±0.20 megapascal (MPa), 1.01±0.23 MPa, and 1.12±0.24 MPa, respectively. The Young's modulus values for groups 2 and 3 showed no statistical significance (P>0.05), However, both groups 2 and 3 were significantly higher than group 1 (P<0.05). At 6% strain, the Young's modulus of the corneas in groups 1, 2, and 3 were: 0.97±0.21, 1.35±0.25, and 1.64±0.44 MPa, respectively, and at 8% strain, the Young's modulus was: 1.29±0.26, 1.72±0.45, 2.20±0.74 MPa, respectively. At 6% and 8% strain, the Young's modulus for the corneas in group 3 was significantly higher than those in both group 1 and group 2 (P<0.05).
Conclusions:
Increasing oxygen concentration during UVA irradiation may improve the efficacy of conventional CXL.
Related Concept Videos
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Enolate Mechanism Conventions
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood
Oxygenic Photosynthesis
Oxygen Requirements and Growth Patterns