Corneal Biomechanical Evaluation After Conventional Corneal Crosslinking With Oxygen Enrichment
Related Experiment Video
Updated: Jan 20, 2026

Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Jia Wang1, Lijun Wang, Zhiwei Li
1Department of Ophthalmology (J.W., L.W., Z.L., K.Z., G.M.), Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong, China; Aier Eye Hospital Group (J.W.), Liaocheng Aier Eye Hospital, Liaocheng, Shandong, China; Department of Ophthalmology (L.W.), Binzhou Medical University Hospital, Binzhou, Shandong, China; and Department of Ophthalmology and Visual Sciences (Y.M.W.), The Chinese University of Hong Kong, Hong Kong, China.
Purpose:
To assess corneal biomechanical changes after conventional corneal crosslinking (CXL), with and without oxygen enrichment.
Methods:
Sixty fresh porcine corneas were randomly divided into group 1 (control), group 2 (conventional CXL), and group 3 (conventional CXL in a high-oxygen environment during ultraviolet A [UVA] irradiation). After crosslinking, a 5-mm wide corneal strip was extracted using a double-bladed knife from 12 to 6'o clock. The Young's modulus of each strip was determined by stress-strain measurements. A comparison between the three groups was performed with a one-way analysis of variance.
Results:
At 4% strain, the Young's modulus of the corneas in groups 1, 2, and 3 were: 0.68±0.20 megapascal (MPa), 1.01±0.23 MPa, and 1.12±0.24 MPa, respectively. The Young's modulus values for groups 2 and 3 showed no statistical significance (P>0.05), However, both groups 2 and 3 were significantly higher than group 1 (P<0.05). At 6% strain, the Young's modulus of the corneas in groups 1, 2, and 3 were: 0.97±0.21, 1.35±0.25, and 1.64±0.44 MPa, respectively, and at 8% strain, the Young's modulus was: 1.29±0.26, 1.72±0.45, 2.20±0.74 MPa, respectively. At 6% and 8% strain, the Young's modulus for the corneas in group 3 was significantly higher than those in both group 1 and group 2 (P<0.05).
Conclusions:
Increasing oxygen concentration during UVA irradiation may improve the efficacy of conventional CXL.
Related Concept Videos
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Enolate Mechanism Conventions
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood
Oxygenic Photosynthesis
Oxygen Requirements and Growth Patterns