Related Experiment Video
Updated: Jan 20, 2026

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
Published on: May 11, 2020
Results of using robotic-assisted navigational system in pedicle screw placement
Hsuan-Yu Chen1,2, Xiu-Yun Xiao3, Chih-Wei Chen2,3
1Department of Orthopedic Surgery, National Taiwan University Hospital, Hsin-Chu branch, Hsinchu City, Taiwan.
Abstract:
Recent technical developments have resulted in robotic-assisted pedicle screw placement techniques. However, the use of robotic-assisted navigational techniques is still subject to controversy. This study aims to assess the accuracy and safety of a self-developed navigation system, the point spine navigation system (PSNS), for robotic-assisted pedicle screw placement surgery. Fifty-nine pedicle screws were implanted in three porcine vertebrae at the T6-T10 and L1-L5 levels, with the assistance of the PSNS. The navigation and planning system provides virtual surgical guide images, including sagittal, coronal, axial, oblique planes, and customized three-dimensional reconstructions for each vertebra to establish accurate pedicle screw trajectories and placement tracts. After pedicle screw placement, post-operative spiral computer tomographic scans were performed and screws were evaluated using the Gertzbein-Robbins classification. Differences between the actual pedicle screw position and pre-operative planning paths, including the angle, shortest distance, and entry trajectory were recorded. The 59 pedicle screw placements were all within a safe zone, and there was no spinal canal perforation or any other damage under postoperative computed tomography image data. Fifty-one screws were categorized as group A, seven screws were noted as group B, and one screw was identified as group E under the Gertzbein-Robbins classification. The mean entry point deviation was 2.71 ± 1.72°, mean trajectory distance was 1.56 ± 0.66 mm, and average shortest distance between two paths was 0.96 ± 0.73 mm. Pedicle placement remains a challenging procedure with high reported incidences of nerve and vascular injuries. The implementation of a robotic-assisted navigational system yields an acceptable level of accuracy and safety for the pedicle screw placement surgery.
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Matrix-Assisted Laser Desorption Ionization (MALDI)
Bystander Effect
Self-Schemas