Related Experiment Video
Updated: Jan 20, 2026

Online Transcranial Magnetic Stimulation Protocol for Measuring Cortical Physiology Associated with Response Inhibition
Published on: February 8, 2018
Reliability of transcranial magnetic stimulation measures of afferent inhibition
Claudia V Turco1, Angelina Pesevski2, Paul D McNicholas2
1Department of Kinesiology, McMaster University, ON, Canada.
Abstract:
Short-latency afferent inhibition (SAI) and long-latency afferent inhibition (LAI) are well-known transcranial magnetic stimulation (TMS) paradigms used to probe the sensorimotor system. To date, there is a paucity of research examining the reliability of these neurophysiological measures. This information is required to validate the utility of afferent inhibition as a biomarker of neural function. The goal of this study was to quantify the absolute reliability, relative reliability, and smallest detectable change (SDC) of SAI and LAI using a test-retest paradigm. 30 healthy individuals (20.9 ± 2.5 years) participated in two sessions (intersession interval of ~7 days). Reliability was assessed with intraclass correlation coefficients (ICC), standard error of measurement (SEMeas), and SDC. The results show that LAI and SAI had poor-to-moderate relative reliability as determined by the ICC, with digital nerve LAI displaying the highest relative reliability (highest ICC with smallest confidence interval). The %SEMeas indicated a large amount of measurement error in all measures of afferent inhibition, with LAI exhibiting more measurement error than SAI. The SDC was large at the individual level (SDCindiv), but analyses showed that the SDC is significantly reduced at the group-level (SDCgroup). Our results indicate that digital nerve LAI is the most reliable outcome to differentiate between individuals within a sample. Further, results suggest that SAI and LAI are not appropriate indicators of individual neurophysiological change across time but can reliably detect changes in group-averaged data providing sample sizes are sufficient.
More Related Videos
14:47Author Spotlight: Combined Peripheral Nerve Stimulation and Controllable Pulse Parameter Transcranial Magnetic Stimulation to Probe Sensorimotor Control and Learning
Published on: April 21, 2023
07:33Measuring Contralateral Silent Period Induced by Single-Pulse Transcranial Magnetic Stimulation to Investigate M1 Corticospinal Inhibition
Published on: August 23, 2022
Related Concept Videos
Reliability and Validity
Feedback Inhibition
Distribution Reliability and Automation
Enzyme Inhibition
Inhibition of Cdk Activity
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...