Related Experiment Video
Updated: Jan 20, 2026

Modeling Hepatitis B Virus Infection in Non-Hepatic 293T-NE-3NRs Cells
Published on: June 5, 2020
Application of Raman spectroscopy in the detection of hepatitis B virus infection
Dongni Tong1, Cheng Chen2, JingJing Zhang3
1Department of Laboratory Medicine, The First Affiliated Hospital of Xinjiang Medical University, Urumuqi 83001, China.
Objective:
Detection of hepatitis B virus (HBV) using Raman spectroscopy.
Methods:
Raman spectroscopy was used to examine the serum samples of 500 patients with HBV and 500 non-HBV persons. First, the adaptive iterative weighted penalty least squares method (airPLS) was used to deduct the fluorescence background in Raman spectra. Then, a principal component analysis (PCA) was used to extract the processed Raman spectra, and a support vector machine (SVM) was used for modeling and prediction. The particle swarm optimization (PSO) algorithm was selected to optimize the parameters of the SVM instead of a traditional grid search. Finally, 600 serum samples were detected by Raman spectroscopy, and the results wereverified using a double-blind method.
Results:
In the Raman spectra, the non-HBV human Raman peaks at 509, 957, 1002, 1153, 1260, 1512, 1648 and 2305 cm-1 were different from those of patients with HBV. The reported accuracy, sensitivity and specificity of the HBV serum model established using airPLS-PCA-PSO-SVM was 93.1%, 100% and 88%, respectively. The two groups were verified by a double-blind method. In the first group sensitivity was 87%, specificity was 92%, and the KAPPA value was 0.79; in the second group sensitivity was 80%, specificity was 79%, and the KAPPA value was 0.59.
Conclusion:
This preliminary study shows that serum Raman spectroscopy combined with the airPLS-PCA-PSO-SVM model can be used for hepatitis B virus detection.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Applications of IR Spectroscopy: Overview
What are Viruses?
Effect of Hepatic Disease on Pharmacokinetics: Dose Adjustments Due to Hepatic Impairment
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...