Related Experiment Video
Updated: Jan 20, 2026

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Time-Resolved Freely Dissolved Concentrations of Semivolatile and Hydrophobic Test Chemicals in In Vitro
Heidi Birch1, Nynke I Kramer2, Philipp Mayer1
1Department of Environmental Engineering , Technical University of Denmark , Bygningstorvet, Building 115 , 2800 Kongens Lyngby , Denmark.
Abstract:
In vitro assays are normally conducted in plastic multiwell plates open to exchange with the ambient air. The concentration of test substances freely available to cells is often not known, can change over time, and is difficult to measure in the small volumes in microplates. However, even a well-characterized toxicological response is of limited value if it cannot be linked to a well-defined exposure level. The aim of this study was to develop and apply an approach for determining time-resolved freely dissolved concentrations of semivolatile and hydrophobic organic chemicals (SVHOCs) in in vitro assays: (1) free fractions were measured by a new medium dilution method and (2) time-resolved loss curves were obtained by measurements of total concentrations in 96-well plates during incubations at 37 °C. Headspace solid-phase microextraction was used as an analytical technique for 24 model chemicals spanning 6 chemical groups and 4-5 orders of magnitude in Kow and Kaw. Free fractions were >30% for chemicals with log Kow < 3.5 and then decreased with increasing log Kow. Medium concentrations declined significantly (>50%) within 24 h of incubation for all 20 chemicals having log Kow > 4 or log Kaw > -3.5 in serum-free medium. Losses of chemicals were lower for medium containing 10% fetal bovine serum, most significantly for chemicals with log Kow > 4. High crossover to neighboring wells also was observed below log Kow of 4 and log Kaw of -3.5. Sealing the well plates had limited effect on the losses but clearly reduced crossover. The high losses and crossover of most tested chemicals question the suitability of multiwell plates for in vitro testing of SVHOCs and call for (1) test systems that minimize losses, (2) methods to control in vitro exposure, (3) analytical confirmation of exposure, and (4) exposure control and confirmation being included in good in vitro reporting standards.
Related Concept Videos
Drug Concentrations: Measurements
Plasma...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
The Integrated Rate Law: The Dependence of Concentration on Time
Phase Transitions: Sublimation and Deposition

