Related Experiment Video
Updated: Jan 20, 2026

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Combination of lead-field theory with cardiac vector direction: ECG imaging of septal ventricular activation
Danila Potyagaylo1, Mikhail Chmelevsky2, Margarita Budanova3
1EP Solutions SA, Yverdon-les-Bains, Switzerland.
Background:
Despite the tremendous progress recently reported in ECG imaging (ECGI), some fundamental challenges are still hindering this non-invasive technology from meeting rising clinical expectations. In the present work, we address one of the major ECGI shortcomings in reconstruction of ventricular activation - the limited accuracy of endocardial and particularly septal mapping.
Methods:
Ten CRT patients (five female, median (min-max) age - 61 (27-78) years) with previously implanted CRT devices underwent ECGI with isolated right ventricular (RV) pacing. In eight patients, the RV pacemaker lead was placed in the middle septal area of the posterior RV wall. Two subjects had a pacing lead in the anteroseptal apical segment, two at septal RVOT, two at septal junction with posterior wall and six in anterolateral segments. Lead positions were exactly known from CT scans, making the respective paced ECG sequences ideal for validation of ECGI endocardial accuracy. Non-invasive mapping was performed for single RV paced beats using original parameters of the CRT device. For non-invasive estimation of the focal origins, we considered the lead-field based fastest route algorithm (FRA) and its combination with the cardiac vector fit (FRA-V). Furthermore, we extended the resulting combined map by incorporating cardiac activation direction (FRA-V-D) provided by the cardiac dipole.
Results:
The median (min-max) localization errors were 14 mm (7-27), 9 mm (7-28) and 11 mm (8-24) for FRA, FRA-V and FRA-V-D, respectively. Notably, in all cases at least one of the considered ECGI methods was able to correctly localize the found excitation origin on the endocardium.
Conclusions:
This preliminary study investigates combination of the rule-based fastest route algorithm with cardiac vector fit and direction for non-invasive imaging of septal ventricular sources. The developed ECGI methodology delivers reasonable reconstruction accuracy with the 10 mm median localization error. These findings suggest potential use of ECGI for challenging clinical cases, where catheter access to the correct cardiac anatomical region plays a crucial role in the execution of the electrophysiological procedure.
Related Concept Videos
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Direction of Acceleration Vectors
Direction Cosines of a Vector