Factors affecting dural sinus density in non-contrast computed tomography of brain
Reza Akhavan1, Bita Abbasi2, Moein Kheirollahi2
1Department of Emergency Medicine, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Abstract:
The possibility of changing the intracranial vasculature computed tomography (CT) attenuation under the influence of variable factors is a long-held unestablished belief. The purpose of this study is to evaluate factors affecting dural sinus density in non-contrast computed tomography of the brain. Patients presented with acute neurologic symptoms to the emergency department were candidates to be enrolled in this study. A region of interest (ROI) measuring 1-2-mm2 recorder (base on sinus size) used to measure the attenuation of each sinus in Hounsfield Unit (HU) and then mean density calculated. CBC, BUN and Cr were extracted from patients' records. Chi-square test, correlation analyze, independent sample unpaired student t-test and one-way ANOVA test and Multivariate logistic regression were used. Positive significant correlation (0.48) was found between the hematocrit level (HCT) and average attenuation in the four sinus segments (P value < 0.0001) and between the HCT and basilar artery attenuation (P value < 0.0001). There was no significant correlation between the age and average attenuation. There was a significant and negative correlation between the BUN/Cr and average attenuation. Using a multivariate analysis on a large sample volume, we conclude that Hgb and HCT are the only factors that have a significant correlation with average sinus attenuation. This correlation is relatively stronger for Hgb in comparison to HCT.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Density
Transcription Factors