Related Experiment Video
Updated: Jan 20, 2026

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Imaging Characteristics of USPIO Nanoparticles (In Vitro and in the Liver of Rats
Xiaohong Ma1, Shuang Wang1, Longbin Hu1
1Diagnostic Radiology, Cancer Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100021, China.
Abstract:
Iron nanoparticles have an increasingly more and more important role in MR molecular imaging due to their novel magnetic and surface chemical properties. They provide new possibilities for noninvasive diagnosis and treatment monitoring, especially for tissues that are rich in macrophages. The smaller size and prolongation of the plasma half-life change the in vivo fate of ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles captured by liver in reticuloendothelial system (RES) or mononuclear phagocytic system (MPS). However, there is still a lack of MR imaging studies on the liver assessing USPIO nanoparticles <5 nm in size to reflect its absorption and clearance properties. In this study, we used MRI to study the in vitro phantom and in vivo rat liver imaging characteristics of USPIO nanoparticles (<5 nm). The results showed that USPIO nanoparticles (<5 nm) could potentially reduce longitudinal and transverse relaxation times and showed similar T 1 relaxation rates compared with commercial gadolinium chelates. In addition, USPIO nanoparticles (<5 nm) in vivo demonstrated both positive (T 1) and negative (T 2) liver contrast enhancement in healthy rats' liver. Furthermore, USPIO nanoparticles showed relatively good in vitro biocompatibility and fast clearance (within 45.17 minutes after intravenous injection) in the normal liver. Taken together, these data might inspire a new personalized and precise diagnostic tool and stimulate new applications for specific targeted molecular probes.
Related Concept Videos
Characteristics of Life
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Characteristics of Fluids
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...