Feasibility and accuracy of SPECT myocardial perfusion imaging in end-stage lung disease

Sanziana R I Schiopu1,2, Mathias Zacherl3, Andrei Todica3

  • 1Department of Internal Medicine V, Ludwig-Maximilians-University Munich, Marchioninistrasse 15, 81377, Munich, Germany. schiopu_s@yahoo.com.

Insights

Regadenoson stress SPECT-myocardial perfusion imaging (MPI) is safe and effective for diagnosing coronary artery disease (CAD) in patients with end-stage lung disease (ELD). This non-invasive test aids in pre-lung transplant decisions.

Area of Science:

  • Cardiology
  • Pulmonology
  • Nuclear Medicine

Background:

  • Coronary artery disease (CAD) increases mortality in patients with chronic lung disease.
  • Non-invasive CAD diagnosis is challenging in advanced lung disease.
  • End-stage lung disease (ELD) patients require accurate CAD assessment for lung transplant eligibility.

Purpose of the Study:

  • To evaluate the feasibility and accuracy of SPECT-myocardial perfusion imaging (MPI) stress testing using regadenoson in ELD patients.
  • To assess the safety and tolerability of regadenoson-induced stress SPECT-MPI in this population.
  • To determine the utility of SPECT-MPI in guiding revascularization decisions before lung transplantation.

Main Methods:

  • Retrospective analysis of 102 ELD patients undergoing lung transplant evaluation (January 2012 - May 2018).
  • All patients underwent stress SPECT-myocardial perfusion imaging (MPI) with regadenoson and coronary angiography.
  • Data on regadenoson-related symptoms and coronary angiography findings were collected.

Main Results:

  • Regadenoson stress SPECT-MPI was well-tolerated, with only 14% experiencing mild symptoms and 2% requiring treatment.
  • Obstructive CAD was identified in 20% of patients.
  • SPECT-MPI findings influenced revascularization decisions in 14 patients with obstructive CAD.

Conclusions:

  • Regadenoson-enhanced SPECT-MPI is a feasible and safe diagnostic tool for CAD in ELD patients.
  • The imaging modality aids in clinical decision-making regarding coronary revascularization prior to lung transplantation.
  • SPECT-MPI can help optimize patient selection for lung transplantation by identifying significant CAD.
Abstract

Related Concept Videos

Improving Translational Accuracy02:07

Improving Translational Accuracy

Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.1K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.6K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
100.1K
Lung Capacity01:47

Lung Capacity

The air in the lungs is measured in volumes and capacities. Lung volume measures reflect the amount of air taken in, released, or left over after a lung function, like a single inhalation. Lung capacity measures are sums of two or more lung volume measures.
56.1K
Accuracy and Precision01:52

Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
14.2K
Accuracy, limits, and approximation01:28

Accuracy, limits, and approximation

Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
1.1K