Rapid ventricular pacing during transcatheter valve procedures using an internal device and programmer: A
Brandon M Jones1, Yash Jobanputra1, Amar Krishnaswamy1
1Robert and Suzanne Tomsich Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
Objectives:
To develop a protocol for using a pre-existing, permanent pacemaker or defibrillator device for rapid ventricular pacing during transcatheter valve procedures and demonstrate feasibility.
Background:
Placement of a passive fixation, temporary pacemaker wire is considered routine during most transcatheter valve procedures to facilitate controlled or rapid ventricular pacing at the time of balloon expansion or valve deployment. Many patients presenting for such procedures have a pre-existing, permanent pacemaker or defibrillator device which could be used for the same function, obviating the need for temporary pacemaker wire placement.
Methods:
We developed a strategy for rapid pacing from the pre-existing device using a programmer during transcatheter valve procedures in consecutive patients over a 3-month period. Complications and clinical outcomes were recorded.
Results:
There were 135 transcatheter valve procedures performed during the study. Of these, 28 (20.7%) had pre-existing devices (17 transcatheter aortic valve replacement, 3 aortic valve-in-valve, 2 mitral valve-in-valve, and 6 balloon aortic valvuloplasty). All patients underwent rapid ventricular pacing using a commercially available device programmer. There were no adverse events related to device pacing and no patients required placement of a temporary pacemaker wire during the procedure. At 30-days follow-up, there were no deaths, one major vascular complication related to arterial access, and one patient with renal failure requiring dialysis.
Conclusion:
Pacing from a commercially available device programmer is safe, feasible, and may reduce both procedural cost and complications such as cardiac tamponade by avoiding placement of a temporary pacemaker lead during transcatheter valve procedures.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Internal Energy
Internal Energy
Internal Receptors
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
External and Internal Respiration