Related Experiment Video
Updated: Jan 20, 2026

Spray-Coated Melanin/PEDOT:PSS Films for Sustainable Organic Electrochemical Transistors
Published on: October 28, 2025
Breaching the 10 Second Barrier of Total Analysis Time for Complex Matrices via Automated Coated Blade Spray
Alexander Kasperkiewicz1, Germán Augusto Gómez-Ríos1, Dietmar Hein2
1Department of Chemistry , University of Waterloo , Waterloo , Ontario N2L 3G1 , Canada.
Abstract:
In the development of modern analytical workflows, parameters such as sample turnaround time, cost of analysis, and ease of use must be prioritized. Automation enables reductions in total analysis time, human intervention, and cost per sample. In this report, a suitable automated coated blade spray (CBS) workflow is proposed for the screening and quantitation of multiple substances (i.e., drugs of abuse and pesticides) in complex matrices. In an attempt to reduce the total sample analysis time, several parameters were investigated, including tandem mass spectrometry (MS) dwell time, CBS spray time, and extraction time. Solid-phase microextraction (SPME) method parameters are explored, such as reduction of extraction time for increased signal-to-noise. Model compounds with a moderately wide range of molecular weights (150-500 Da), polarities, and structural diversity were selected in order to monitor analytical figures of merit during method optimization. The resultant automated CBS method proved capable of analyzing the model compounds in human urine in under 10 s total analysis time with excellent accuracy (95-120%) and precision (RSD < 12%). As an application, an automated method for the screening and quantitation of more than 150 pesticides from apple juice was demonstrated on both triple quadrupole and orbitrap instruments in under 15 s total sample analysis time.
More Related Videos
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Protein Complex Assembly
Many viruses self-assemble into a fully functional unit using the infected host cell to...
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...
Clathrin Coated Vesicles
COP Coated Vesicles

