Crack Monitoring in Resonance Fatigue Testing of Welded Specimens Using Digital Image Correlation
Published on: September 29, 2019
Development of a zoomorphic test specimen for constancy testing on digital X-ray systems in veterinary radiology
Gerrit Pöhlmann1, Matthias Lüpke1, Christian Seiler2
1Institute for General Radiology and Medical Physics, University of Veterinary Medicine Hannover, Bischofsholer Damm 15, Haus 102, 30173, Hannover, Germany.
Background:
Technical failures and incorrect usage of digital X-ray systems may lead to a decreasing image quality, artefacts and a higher dose exposure of staff and patients. Although there are no regulations regarding constancy testing in veterinary radiology all operators are required to avoid unnecessary exposure. The aim of this study was to develop a reasonably inexpensive zoomorphic 3D-printed test specimen for constancy testing that allows the detection of changing image quality by visual analysis. Primarily, a calibration curve of the attenuation factor of the 3D-printing material (ZP150) was determined. MATLAB converted every pixel value of a thorax X-ray image of a Beagle dog into an equivalent thickness of printing material. The thickness distribution was printed using a 3D-printer. This printed test specimen was additionally provided with five thin aluminium discs to simulate lung nodules. To evaluate the usability for constancy testing 12 X-ray images of the test specimen were made. Two images (reference and control) were taken with the minimum dose in order to obtain images suitable for diagnosis purposes. Eight images were taken with a dose differing 30-140% from the reference dose by varying current-time product (mAs) or tube voltage (kVp). Two images were taken with the same parameters as the reference image but edited with different image processing. Six veterinarians (general practitioners) evaluated ten chosen structures in the X-ray images in a Visual Grading Analysis and scored the image quality of these structures for every image in comparison to the reference image. A Visual Grading Analysis Score was calculated and statistically analysed.
Results:
A higher current-time product led to a negligibly better evaluation of the X-ray image. The lower the current-time product the worse the X-ray images were scored. Likewise, both increasing and decreasing of the tube voltage led to lower scores.
Conclusions:
A zoomorphic test specimen can be used for constancy testing of digital X-ray systems in veterinary medicine. Especially a lower dose can be recognised due to deviation in the image quality when compared to the reference image. The 3D-printed test specimen is less expensive than test equipment used in human medicine.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Perceptual Constancy
Size constancy is the recognition that an object remains the same size, even when its image on the retina changes. For instance, a bus is perceived to be large enough to carry people, even if it looks tiny from...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
In Vitro Drug Release Testing: Overview, Development and Validation
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
X-ray Imaging