Intestinal delta-6-desaturase activity determines host range for Toxoplasma sexual reproduction

Bruno Martorelli Di Genova1, Sarah K Wilson1, J P Dubey2

  • 1Department of Medical Microbiology and Immunology, University of Wisconsin-Madison, Madison, Wisconsin, United States of America.

Plos Biology
|August 21, 2019
PubMed

Related Concept Videos

The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.1K
Reproductive Cloning01:27

Reproductive Cloning

Reproductive cloning is the process of producing a genetically identical copy—a clone—of an entire organism. While clones can be produced by splitting an early embryo—similar to what happens naturally with identical twins—cloning of adult animals is usually done by a process called somatic cell nuclear transfer (SCNT).
Somatic Cell Nuclear Transfer
In SCNT, an egg cell is taken from an animal and its nucleus is removed, creating an enucleated egg. Then a somatic...
32.6K
Range00:59

Range

The range is one of the measures of variation. It can be defined as the difference between a dataset's highest and lowest values. For example, in the study of seven 16-ounce soda cans, the filled volume of soda was measured, thus producing the following amount (in ounces) of soda:
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
13.8K
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
693
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
847
Sexually Transmitted Infections01:26

Sexually Transmitted Infections

Sexually transmitted infections (STIs) are diseases transmitted primarily through unsafe sexual interactions. Bacteria, viruses, or parasites cause them and can result in severe health complications if untreated.ChlamydiaThe bacterium Chlamydia trachomatis is responsible for the disease Chlamydia, the most common STI in the United States. This peculiar pathogen requires human cells to reproduce, residing intracellularly. The initial infection often goes unnoticed because it typically does not...
948