Related Experiment Video For Cholangiocarcinoma
Updated: Jan 20, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
Split-bolus vs. multiphasic contrast bolus protocol in patients with pancreatic cancer or cholangiocarcinoma
Hanna Muenzfeld1, Samy Mahjoub1, Robert Roehle2
1Department of Radiology, Charité - Universitätsmedizin Berlin, Germany.
Purpose:
To investigate the image quality, diagnostic accuracy, and dose reduction potential of a split-bolus protocol(SBP) compared with a multiphasic protocol(MPP) in the detection of recurrent or progressive pancreatic ductal adenocarcinoma(PDAC) or cholangiocarcinoma(CC) using contrast- enhanced computed tomography(CECT).
Materials And Methods:
This prospective study included 56 patients who underwent CECT, 28 with our institutional standard MPP(100 ml contrast bolus) and 28 with a novel SBP(110 ml). Radiation exposure was determined in terms of total dose- length product(DLP) and computed tomography dose index(CTDI). Image quality was measured objectively by analysis of attenuation in Hounsfield units(HU) in regions of interest(ROIs) and subjectively by two blinded readers using a Likert scale. Diagnostic accuracy and interreader variability were tested.
Results:
The total DLP of the SBP group(498.1 ± 43.7 mGy*cm) was significantly lower than in the MPP group(1,092.5 ± 106.9 mGy*cm; p < 0.001). The SBP showed higher contrast enhancement of all critical anatomical structures including portal vein, liver, and pancreas compared with the MPP, except for the aorta(SBP: 326.9 ± 15.7 HU vs. MPP: 246.7 ± 12.2 HU; p < 0.001). Subjective analysis revealed poorer image quality ratings for important landmarks with the MPP (resection surface: p = 0.624, portal vein: p = 0.395, liver p = 0.361). The two blinded readers correlated significantly. Sensitivity, specificity, positive and negative predictive values (PPV/NPV), and overall interreader variabilities correlated significantly. Furthermore, significantly fewer slices per exam were required for the SBP(1,823 vs. 3,235; p < 0.001).
Conclusion:
The SBP provides the same image quality and diagnostic accuracy as an MPP while significantly lowering radiation exposure in CT follow-up of PDAC or CC.
More Related Videos
06:59Establishment of Zebrafish Patient-Derived Xenografts from Pancreatic Cancer for Chemosensitivity Testing
Published on: May 12, 2023
09:56Patient-derived Heterogeneous Xenograft Model of Pancreatic Cancer Using Zebrafish Larvae as Hosts for Comparative Drug Assessment
Published on: April 30, 2019
Related Concept Videos
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...